LifeShield infusion safety software
Infusion safety software. Attributes come from ICU Medical's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-27 Device includes support for firmware/software updates PID-275 Device includes remotely-initiated firmware/software updates PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Cloud Application Firmware Generic Application Local Application Local Service User Interface Web Application
Attributes: assets
Report Data Software Configuration Software Update Telemetry Data User Data
Attributes: dataflows
LifeShield to Infusion Pumps (drug library and software updates) Pharmacy to Infusion Pumps (drug library protocols pushed fleet-wide)
Matched threat intel
Top 20 of 22
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what ICU Medical has said.
| # | Advisory | Date | Shared | ICU Medical status |
|---|---|---|---|---|
| 1 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-41113 shared attributes: Remote access, User accounts, Field-updatable firmware, Hospital network +9 | No response from manufacturer |
| 2 | A DICOM viewer that did not check its update server certificate | Feb 20, 2025 | Same property (MITRE EMB3D)PID-27511 shared attributes: Field-updatable firmware, Cloud connectivity, User accounts, Hospital network +7 | No response from manufacturer |
| 3 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Same property (MITRE EMB3D)PID-4118 shared attributes: Cloud connectivity, User accounts, Remote access, Hospital network +4 | No response from manufacturer |
| 4 | Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their origin | Feb 27, 2018 | Same property (MITRE EMB3D)PID-2755 shared attributes: Field-updatable firmware, Cloud connectivity, Device includes support for firmware/software updates (PID-27), Generic Application +1 | No response from manufacturer |
| 5 | MicroDicom DICOM Viewer 2024.03 fails to validate its update server certificate | Feb 6, 2025 | Same property (MITRE EMB3D)PID-2754 shared attributes: Field-updatable firmware, Device includes support for firmware/software updates (PID-27), Local Application, Software Update | No response from manufacturer |
| 6 | GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | Same property (MITRE EMB3D)PID-4115 shared attributes: User accounts, Remote access, Hospital network, Generic Application +1 | No response from manufacturer |
| 7 | Medtronic MyCareLink 24950 and 24952 monitors store upload credentials in a recoverable format | Aug 7, 2018 | Same property (MITRE EMB3D)PID-4112 shared attributes: Cloud connectivity, Telemetry Data | No response from manufacturer |
| 8 | BD Alaris System with Guardrails Suite MX has unsigned wireless firmware and tamperable datasets | Jul 13, 2023 | 11 shared attributesInfusion and medication family, Infusion, Field-updatable firmware, Hospital network +7 | No response from manufacturer |
| 9 | B. Braun SpaceCom and Battery Pack SP with Wi-Fi carry 11 flaws from XSS to unsigned firmware | Oct 22, 2020 | 9 shared attributesInfusion and medication family, Infusion, Field-updatable firmware, User accounts +5 | No response from manufacturer |
| 10 | Baxter Sigma Spectrum infusion pumps and wireless battery modules carry hard-coded passwords | Jun 18, 2020 | 11 shared attributesInfusion and medication family, Infusion, User accounts, Hospital network +7 | No response from manufacturer |
| 11 | Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | 10 shared attributesUser accounts, Field-updatable firmware, Device includes authenticated services (PID-332), Device exposes remote network services (PID-41) +6 | No response from manufacturer |
| 12 | Hidden BLE commands can switch off a vagus nerve stimulator’s safety limits | Aug 11, 2026 | 9 shared attributesUser accounts, Field-updatable firmware, Remote access, Device exposes remote network services (PID-41) +5 | No response from manufacturer |
| 13 | BD Alaris Gateway Workstation accepts malicious files during firmware update | Jun 13, 2019 | 8 shared attributesInfusion and medication family, Infusion, Field-updatable firmware, Hospital network +4 | No response from manufacturer |
| 14 | Smiths Medical CADD-Solis Medication Safety Software hands users elevated SQL database rights | Nov 1, 2016 | 8 shared attributesInfusion and medication family, Infusion, User accounts, Hospital network +4 | No response from manufacturer |
| 15 | BD Alaris Infusion Central leaves a recoverable database password after installation | Feb 16, 2023 | 6 shared attributesInfusion and medication family, Infusion, User accounts, Hospital network +2 | No response from manufacturer |
| 16 | B. Braun OnlineSuiteplus inherits a Keycloak password reset flaw, CVE-2026-18963 | Sep 29, 2026 | 5 shared attributesInfusion and medication family, Infusion, User accounts, Cloud Application +1 | No response from manufacturer |
| 17 | BD Alaris 8015 PC Unit and Systems Manager session authentication flaw can knock pumps off wireless | Nov 12, 2020 | 6 shared attributesInfusion and medication family, Infusion, Hospital network, Local Application +2 | No response from manufacturer |
| 18 | BD rates Meltdown and Spectre low impact across its instrument and Pyxis lines | Jan 5, 2018 | 4 shared attributesInfusion and medication family, Infusion, Firmware, Software Update | No response from manufacturer |
| 19 | Philips Engage Software 6.2.1 and prior let authenticated users view business contact data | Jan 6, 2022 | 4 shared attributesUser accounts, Cloud connectivity, Cloud Application, User Data | No response from manufacturer |
| 20 | Nine medtech companies have disclosed cyber incidents in 2026 | Aug 21, 2026 | 3 shared attributesCloud Application, Web Application, User Data | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-202 Exploitable System Network Stack Component TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-315 Password Retrieval Mechanism Abused TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-284 Improper Access Control CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-321 Use of Hard-coded Cryptographic Key CWE-345 Insufficient Verification of Data Authenticity CWE-434 Unrestricted Upload of File with Dangerous Type CWE-494 Download of Code Without Integrity Check CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort