Centricity Cardio Enterprise
Cardiology imaging and workflow software. Attributes come from GE HealthCare's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
Attributes: component types
Generic Application Local Application Local Service User Interface
Attributes: assets
Patient Data Report Data User Data
Attributes: dataflows
Cardiology procedure modules to Centricity Cardio Enterprise (report and billing data) Centricity Cardio Enterprise to Registry (registry data submission) Centricity Cardio Enterprise to Xeleris (user name and patient context) Implant and follow-up data to Cardiac Rhythm Management module Imported measurement values to physician report MUSE NX to Centricity Cardio Workflow (ECG studies) Mac-Lab to Centricity Cardio Enterprise (procedural documentation and registry data) Third-party hemodynamic devices to Centricity Cardio Enterprise
Matched threat intel
9
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what GE HealthCare has said.
| # | Advisory | Date | Shared | GE HealthCare status |
|---|---|---|---|---|
| 1 | Stored passwords recoverable in a Siemens imaging platform | Feb 10, 2026 | Same signals5 shared attributes: User accounts, Handles patient data, Hospital network, Application-level software is present and running on the device (PID-31) +1 | No response from manufacturer |
| 2 | Hillrom Welch Allyn cardiology software let SSO users log in as any AD account without a password | Dec 9, 2021 | 7 shared attributesCardiology and implants family, Cardiology, User accounts, Physiological waveform processing +3 | No response from manufacturer |
| 3 | MIM Assistant and MIM Client 7.2.10 and 7.3.3 open to XXE through DICOM RT tags | Sep 19, 2023 | 7 shared attributesImag, Workflow, DICOM or image parsing, File import +3 | No response from manufacturer |
| 4 | Philips IntelliSpace Cardiovascular and Xcelera store credentials in cleartext | Nov 14, 2017 | 7 shared attributesCardiology and implants family, User accounts, Handles patient data, DICOM or image parsing +3 | No response from manufacturer |
| 5 | Siemens Healthineers fixes seven web service flaws in syngo Dynamics before VA40G HF01 | Nov 17, 2022 | 5 shared attributesCardiology and implants family, Cardiology, Imag, Hospital network +1 | No response from manufacturer |
| 6 | Change Healthcare, McKesson and Horizon Cardiology installs ship with insecure file permissions | Aug 29, 2019 | 5 shared attributesCardiology and implants family, Cardiology, User accounts, Generic Application +1 | No response from manufacturer |
| 7 | Philips IntelliSpace Cardiovascular and Xcelera servers allow privilege escalation through writable executable folders | Aug 14, 2018 | 4 shared attributesCardiology and implants family, Cardiology, User accounts, Local Application | No response from manufacturer |
| 8 | Philips discloses vulnerabilities in PageWriter TC10 to TC70 cardiographs | Aug 16, 2018 | 4 shared attributesCardiology and implants family, Physiological waveform processing, Handles patient data, Hospital network | No response from manufacturer |
| 9 | Philips lists Flex Cardio, XperIM and SensaVue under Follina MSDT flaw CVE-2022-30190 | Jun 30, 2022 | 3 shared attributesCardiology and implants family, Cardiology, Local Application | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-311 Default Credentials TID-317 Predictable Cryptographic Key TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-284 Improper Access Control CWE-294 Authentication Bypass by Capture-replay CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-427 Uncontrolled Search Path Element CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort