Nx2me Connected Health
Connected health software platform. Attributes come from Fresenius Medical Care's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Attributes: component types
API Generic Application Generic Hardware Library Local Service Mobile Application
Attributes: interface types
Cellular TLS WiFi
Attributes: assets
Patient Data Telemetry Data
Attributes: dataflows
Cycler to Nx2me app (treatment information) Nx2me app to clinicians (patient health data) Patient to clinicians via bi-directional messaging
Matched threat intel
11
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Fresenius Medical Care has said.
| # | Advisory | Date | Shared | Fresenius Medical Care status |
|---|---|---|---|---|
| 1 | Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-4119 shared attributes: Wireless connectivity, Handles patient data, Mobile app, Remote access +5 | No response from manufacturer |
| 2 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-4119 shared attributes: Handles patient data, Remote access, Wireless connectivity, Cloud connectivity +5 | No response from manufacturer |
| 3 | BPL PWS-01-BT weighing scale sends unencrypted, unauthenticated BLE data to the Be Well app | Sep 10, 2024 | Same signals6 shared attributes: Health, Wireless connectivity, Mobile app, Home use +2 | No response from manufacturer |
| 4 | Apollo Pharmacy APG-01 BT glucose meter sends readings over BLE in cleartext | Jun 18, 2026 | Same property (MITRE EMB3D)PID-4116 shared attributes: Wireless connectivity, Handles patient data, Home use, Mobile app +2 | No response from manufacturer |
| 5 | Philips IntelliBridge EC40 and EC80 hubs allow weak SSH ciphers | Nov 14, 2019 | Same property (MITRE EMB3D)PID-41136 shared attributes: Remote access, Handles patient data, Device exposes remote network services (PID-41), Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +2 | No response from manufacturer |
| 6 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-4115 shared attributes: Remote access, Wireless connectivity, Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) +1 | No response from manufacturer |
| 7 | Philips IntelliVue MX40 WLAN monitors can drop local alarming after 802.11 faults | Sep 12, 2017 | Same signals2 shared attributes: Wireless connectivity, WiFi | No response from manufacturer |
| 8 | Philips Veradius Unity, Pulsera and Endura Dual WAN routers use weak encryption | Dec 19, 2019 | Same property (MITRE EMB3D)PID-41132 shared attributes: Wireless connectivity, Generic Hardware | No response from manufacturer |
| 9 | Baxter Phoenix hemodialysis system sends treatment and prescription data in cleartext | Jun 18, 2020 | Exposed to the same EMB3D threatTID-4113 shared attributes: Handles patient data, Generic Application, Patient Data | No response from manufacturer |
| 10 | Philips HealthSuite Health Android app uses encryption too weak for its data | Dec 6, 2018 | 6 shared attributesHealth, Mobile app, Home use, Handles patient data +2 | No response from manufacturer |
| 11 | Philips lists connected toothbrushes, a shaver and an espresso machine under SweynTooth BLE flaws | Feb 20, 2020 | 5 shared attributesConnected, Wireless connectivity, Home use, Mobile app +1 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-210 Device Vulnerabilities Unpatchable TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-476 NULL Pointer Dereference CWE-522 Insufficiently Protected Credentials CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort