Merlin.net PCN HF Portal
Remote monitoring web portal. Attributes come from Abbott's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Cloud Application Local Application Local Service Sensor Modules User Interface Web Application
Attributes: interface types
TCP
Attributes: assets
Patient Data Sensor Data Software Configuration
Attributes: dataflows
CardioMEMS HF System to Merlin.net PCN HF Portal (pulmonary artery pressure patient data) Merlin.net PCN HF Portal to Clinician via web interface Merlin.net PCN HF Portal to EHR system via EHRDirect Data Services
Matched threat intel
Top 20 of 25
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Abbott has said.
| # | Advisory | Date | Shared | Abbott status |
|---|---|---|---|---|
| 1 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-31114 shared attributes: Portal, Patient or study database, Handles patient data, Cloud connectivity +10 | No response from manufacturer |
| 2 | Innokas VC150 vital signs monitor accepts HL7 injection and stored XSS | Jan 7, 2021 | Same property (MITRE EMB3D)PID-3118 shared attributes: Patient monitoring family, Monitor, HL7 or FHIR integration, Web interface +4 | No response from manufacturer |
| 3 | Unauthenticated SQL injection into an imaging database, base score 9.8 | Dec 6, 2024 | Exposed to the same EMB3D threatTID-32010 shared attributes: Patient or study database, Handles patient data, Remote access, Web interface +6 | No response from manufacturer |
| 4 | Philips EncoreAnywhere exposes sensitive data in its HTTP headers | May 17, 2018 | Same property (MITRE EMB3D)PID-3115 shared attributes: Cloud connectivity, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application +1 | No response from manufacturer |
| 5 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3115 shared attributes: Web interface, Hospital network, Device includes the usage of a web/HTTP applications (PID-311), Web Application +1 | No response from manufacturer |
| 6 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, TCP | No response from manufacturer |
| 7 | Baxter PrismaFlex and PrisMax send treatment data to EMR systems without encryption or authentication | Jun 18, 2020 | Same property (MITRE EMB3D)PID-4114 shared attributes: Hospital network, TCP, Patient Data, Software Configuration | No response from manufacturer |
| 8 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | 11 shared attributesPatient monitoring family, Remote, Monitor, Cloud connectivity +7 | No response from manufacturer |
| 9 | GE CARESCAPE, ApexPro and CIC monitoring systems carry hard-coded SMB credentials and five more critical flaws | Jan 23, 2020 | 12 shared attributesPatient monitoring family, Monitor, Remote access, Web interface +8 | No response from manufacturer |
| 10 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | 10 shared attributesPortal, Web interface, Handles patient data, Cloud connectivity +6 | No response from manufacturer |
| 11 | Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | 9 shared attributesPortal, Web interface, HL7 or FHIR integration, Handles patient data +5 | No response from manufacturer |
| 12 | Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | 10 shared attributesPatient monitoring family, Monitor, Hospital network, Handles patient data +6 | No response from manufacturer |
| 13 | Weak API input validation opens a monitoring platform to denial of service | Jul 17, 2025 | 9 shared attributesPatient monitoring family, Monitor, Remote access, Cloud connectivity +5 | No response from manufacturer |
| 14 | BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | 6 shared attributesWeb interface, Hospital network, Device includes the usage of a web/HTTP applications (PID-311), Web Application +2 | No response from manufacturer |
| 15 | Qualcomm Life Capsule products inherit Allegro RomPager cookie flaw scored 9.8 | Aug 28, 2018 | 6 shared attributesWeb interface, Hospital network, Device includes the usage of a web/HTTP applications (PID-311), Local Service +2 | No response from manufacturer |
| 16 | Philips lists Zenition 70 and VitalSky under Terrapin SSH flaw CVE-2023-48795 | Apr 8, 2024 | 5 shared attributesPatient monitoring family, Remote, Monitor, Remote access +1 | No response from manufacturer |
| 17 | Philips Tasy EMR HTML5 has two SQL injection flaws that expose patient data | Nov 4, 2021 | 6 shared attributesPatient or study database, Handles patient data, Web interface, Web Application +2 | No response from manufacturer |
| 18 | Philips lists end of life Vue PACS and IntelliBridge versions under jQuery CVE-2020-11023 | Feb 21, 2025 | 4 shared attributesPatient monitoring family, Remote, Monitor, Web interface | No response from manufacturer |
| 19 | Philips lists PIC iX and Focal Point under Chromium ANGLE zero day CVE-2024-2883 | Apr 5, 2024 | 5 shared attributesPatient monitoring family, Monitor, Web interface, Hospital network +1 | No response from manufacturer |
| 20 | Philips lists PIC iX and IntelliSpace ECG under Chromium sandbox zero day CVE-2025-2783 | Apr 3, 2025 | 4 shared attributesPatient monitoring family, Web interface, Hospital network, Web Application | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-210 Device Vulnerabilities Unpatchable TID-213 Faulty FW/SW Update Integrity Verification TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-306 Sandboxed Environments Escaped TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-324 HTTP Direct Object Reference TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-294 Authentication Bypass by Capture-replay CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-476 NULL Pointer Dereference CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort