Liberta RC DBS System
Rechargeable deep brain stimulation system. Attributes come from Abbott's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-23 Device includes OS/kernel PID-27 Device includes support for firmware/software updates PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
iOS companion app: iOS app iOS
Attributes: component types
API Battery Firmware Generic Application Local Application Local Service Mobile Application Operating System User Interface
Attributes: interface types
Unknown Wireless
Attributes: assets
Software Code Software Configuration Software Update
Attributes: dataflows
Clinician programmer to IPG for device programming Clinician to patient device via remote programming Patient controller to IPG for therapy adjustment Software update from Abbott Medical to generator
Matched threat intel
Top 20 of 21
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Abbott has said.
| # | Advisory | Date | Shared | Abbott status |
|---|---|---|---|---|
| 1 | A heart pump controller drew a Class I recall with no attacker in sight | Oct 14, 2025 | Same property (MITRE EMB3D)PID-2310 shared attributes: Therapy delivery, Named operating system, Remote access, Wireless connectivity +6 | No response from manufacturer |
| 2 | Medtronic MyCareLink Smart 25000 reader allows Bluetooth authentication bypass and unsigned firmware | Dec 10, 2020 | Same property (MITRE EMB3D)PID-279 shared attributes: Wireless connectivity, Mobile app, Field-updatable firmware, Firmware +5 | No response from manufacturer |
| 3 | Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | 12 shared attributesStimulation, Wireless connectivity, Therapy delivery, Field-updatable firmware +8 | No response from manufacturer |
| 4 | Hidden BLE commands can switch off a vagus nerve stimulator’s safety limits | Aug 11, 2026 | 11 shared attributesWireless connectivity, Therapy delivery, Field-updatable firmware, Mobile app +7 | No response from manufacturer |
| 5 | Abbott ICDs and CRT-Ds allow RF authentication bypass and battery drain | Apr 17, 2018 | 10 shared attributesWireless connectivity, Therapy delivery, Field-updatable firmware, Remote access +6 | No response from manufacturer |
| 6 | Abbott Accent, Anthem, Assurity and Allure pacemakers get firmware fix for RF authentication bypass | Aug 29, 2017 | 9 shared attributesWireless connectivity, Therapy delivery, Field-updatable firmware, Device includes support for firmware/software updates (PID-27) +5 | No response from manufacturer |
| 7 | A 9.8 in a power wheelchair: BLE takeover with no authentication | Dec 30, 2025 | 9 shared attributesWireless connectivity, Therapy delivery, Field-updatable firmware, Mobile app +5 | No response from manufacturer |
| 8 | Baxter warns of a Newmar radio PIM file flaw in Connex vital signs monitors | Feb 18, 2026 | 6 shared attributesWireless connectivity, Field-updatable firmware, Device includes support for firmware/software updates (PID-27), Wireless +2 | No response from manufacturer |
| 9 | CARTO 3 Versions 6 and 7.1 run vulnerable Print Spooler, fixed in Security Service Pack 4 | Nov 23, 2022 | 5 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System, Local Service +1 | No response from manufacturer |
| 10 | Biosense Webster CARTO 3 V6 SP3 applies Windows patches and antivirus updates | Jan 8, 2021 | 5 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System, Local Application +1 | No response from manufacturer |
| 11 | CARTO 3 V4 systems lack Windows patches; Biosense Webster offers free V6 upgrade | Apr 9, 2018 | 5 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System, Local Application +1 | No response from manufacturer |
| 12 | Olympus validates MS17-010 for Knowledge Exchange, EndoCapsule and nStream | May 19, 2017 | 4 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System, Software Update | No response from manufacturer |
| 13 | Medtronic warns of TiYunZong vulnerability on CT900 tablets running clinician programmer apps | Nov 19, 2020 | 6 shared attributesMobile app, Therapy delivery, Named operating system, Operating System +2 | No response from manufacturer |
| 14 | Boston Scientific says containment is holding, expects some shipping this week | Aug 30, 2026 | 6 shared attributesDevice includes OS/kernel (PID-23), Application-level software is present and running on the device (PID-31), Device includes interactive applications, services, or user interfaces (PID-33), Mobile Application +2 | No response from manufacturer |
| 15 | Baxter says every ExactaMix compounder version is exposed to PrintNightmare | Jul 23, 2021 | 4 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System, Local Service | No response from manufacturer |
| 16 | Karl Storz AIDA and AIDA C ship with HD Graphics Control Panel hotkeys enabled | Oct 30, 2024 | 4 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System, Local Application | No response from manufacturer |
| 17 | Medtronic superDimension navigation system runs on unsupported Windows versions | Jan 19, 2023 | 4 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System, Local Application | No response from manufacturer |
| 18 | Vyaire CareFusion Upgrade Utility loads planted DLLs on Windows XP systems | Feb 6, 2018 | 4 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Local Application, Operating System | No response from manufacturer |
| 19 | Baxter Starling fluid monitor runs unsupported Windows Embedded Compact 7 | Jun 1, 2026 | 3 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System | No response from manufacturer |
| 20 | Philips lists Holter SW, ST80i and Focal Point under Windows CLFS zero-day CVE-2022-37969 | Oct 20, 2022 | 3 shared attributesNamed operating system, Device includes OS/kernel (PID-23), Operating System | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-276 Incorrect Default Permissions CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-345 Insufficient Verification of Data Authenticity CWE-427 Uncontrolled Search Path Element CWE-494 Download of Code Without Integrity Check CWE-522 Insufficiently Protected Credentials CWE-798 Use of Hard-coded Credentials