AED program management software. Attributes come from ZOLL's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Battery Generic Application Generic Hardware Local Application Local Service Mobile Application Sensor Modules User Interface Web Application
Attributes: interface types
Cellular
Attributes: assets
Log Data Report Data Telemetry Data User Data
Attributes: dataflows
AEDtrax to PlusTrac over cellular: daily AED status updates AEDtrax to PlusTrac: buffered data transferred when cellular coverage is restored PlusTrac to Mobile Device: automatic alerts and notifications ZOLL AED 3 / Powerheart G5 to PlusTrac via Rescue Ready monitor: remote reporting
Matched threat intel
10
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what ZOLL has said.
| # | Advisory | Date | Shared | ZOLL status |
|---|---|---|---|---|
| 1 | Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | Same property (MITRE EMB3D)PID-3116 shared attributes: Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application +2 | No response from manufacturer |
| 2 | Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-4118 shared attributes: Wireless connectivity, User accounts, Mobile app, Remote access +4 | No response from manufacturer |
| 3 | Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | Same property (MITRE EMB3D)PID-3117 shared attributes: Device includes the usage of a web/HTTP applications (PID-311), Device includes authenticated services (PID-332), Application-level software is present and running on the device (PID-31), Device exposes remote network services (PID-41) +3 | No response from manufacturer |
| 4 | Change Healthcare PeerVue Web Server leaks technical details in HTTP error messages | Oct 4, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, Log Data | No response from manufacturer |
| 5 | Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flaws | Sep 17, 2020 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 6 | BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | Same property (MITRE EMB3D)PID-3114 shared attributes: User accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 7 | B. Braun SpaceStation with SpaceCom module has an open redirect in its web server | Mar 23, 2017 | Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application, Generic Hardware | No response from manufacturer |
| 8 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | 9 shared attributesCloud connectivity, User accounts, Web interface, Remote access +5 | No response from manufacturer |
| 9 | Cl0p lists Philips among nearly 50 victims of its PTC Windchill campaign | Aug 14, 2026 | 11 shared attributesCloud connectivity, User accounts, Remote access, Web interface +7 | No response from manufacturer |
| 10 | EMS patient-care app reflects unsanitized input into a WebView | Feb 10, 2026 | 9 shared attributesMobile app, Cloud connectivity, Remote access, User accounts +5 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-221 Authentication Bypass By Message Replay TID-226 Device leaks security information in logs TID-304 Manipulate Runtime Environment TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection
CWE weaknesses
CWE-1188 Insecure Default Initialization of Resource CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-321 Use of Hard-coded Cryptographic Key CWE-502 Deserialization of Untrusted Data CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-916 Use of Password Hash With Insufficient Computational Effort