LIVE FEED
CISA added CVE-2026-90817, a critical REDCap flaw requiring no authentication, to its Known Exploited Vulnerabilities catalog November 18 after an unidentified actor used it to deploy the XMRig cryptominer; the research data platform drew a year-long China-nexus intrusion Google reported in June. The extortion group Falcon claimed a 104.76 GB haul from Fisher & Paykel Healthcare November 23, including device documentation and a full Salesforce CRM export, a month after the company confirmed a narrower breach limited to two employee email accounts. The extortion group n0n named GRAIL and Guardant Health, two oncology diagnostics companies, in sequential leak-site listings November 19 and 20, claiming provider and order records; neither company has confirmed the claims. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers and medical and insurance information. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop. CISA added CVE-2026-90817, a critical REDCap flaw requiring no authentication, to its Known Exploited Vulnerabilities catalog November 18 after an unidentified actor used it to deploy the XMRig cryptominer; the research data platform drew a year-long China-nexus intrusion Google reported in June. The extortion group Falcon claimed a 104.76 GB haul from Fisher & Paykel Healthcare November 23, including device documentation and a full Salesforce CRM export, a month after the company confirmed a narrower breach limited to two employee email accounts. The extortion group n0n named GRAIL and Guardant Health, two oncology diagnostics companies, in sequential leak-site listings November 19 and 20, claiming provider and order records; neither company has confirmed the claims. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers and medical and insurance information. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop.
Wednesday, November 25, 2026 Issue #524  ·  Est. 2025
Independent brief for device makers

Quality Manager

Cloud-based QC data management service. Attributes come from Radiometer's own public documentation for this product.

Attributes

Platform
Windows Windows 7 Web browser: Google Chrome Web browser: Internet Explorer 11 Web browser: Microsoft Edge
Attributes: materials
Internet Explorer 11
Attributes: component types
API Cloud Application Cloud Service Firmware Library Local Application Local Service Operating System User Interface Web Application
Attributes: interface types
TCP TLS
Attributes: assets
Calibration Data Credentials Report Data Telemetry Data Tokens User Data
Attributes: dataflows
ABL analyzers to Quality Manager: daily and monthly QC performance in real time ABL analyzers to Radiometer servers (Quality Manager) over encrypted connection: performance, calibration and QC data Customer browser to Quality Manager: inspect, process and report QC data Customer to Microsoft Azure AD: sign-in authentication for customer portal Radiometer to Customer via e-mail: invitation and one-time password for sign-in

Matched threat intel

Top 20 of 101

Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Radiometer has said.

#AdvisoryDateSharedRadiometer status
1User enumeration on the CareLink Network, found at a conferenceDec 4, 2025Same property (MITRE EMB3D)PID-31110 shared attributes: Service, Cloud connectivity, User accounts, Web interface +6No response from manufacturer
2BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated usersMay 24, 2018Same property (MITRE EMB3D)PID-33217 shared attributes: User accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Device includes passwords to authenticate the users (PID-3321) +3No response from manufacturer
3Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flawsApr 30, 2019Same property (MITRE EMB3D)PID-3117 shared attributes: Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application +3No response from manufacturer
4Philips iSite and IntelliSpace PACS carry default credentials in third-party softwareNov 8, 2018Same property (MITRE EMB3D)PID-33215 shared attributes: Off-the-shelf software, User accounts, Device includes passwords to authenticate the users (PID-3321), TCP +1No response from manufacturer
5Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server filesOct 15, 2026Same property (MITRE EMB3D)PID-3326 shared attributes: Device includes the usage of a web/HTTP applications (PID-311), Device includes authenticated services (PID-332), Device exposes remote network services (PID-41), Web Application +2No response from manufacturer
6Medtronic MyCareLink 24950 and 24952 monitors store upload credentials in a recoverable formatAug 7, 2018Same property (MITRE EMB3D)PID-33215 shared attributes: Cloud connectivity, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), Cloud Service, Credentials +1No response from manufacturer
7Softneta MedDream PACS allows unauthenticated remote code executionSep 5, 2023Same property (MITRE EMB3D)PID-33214 shared attributes: User accounts, Web interface, Device includes passwords to authenticate the users (PID-3321), CredentialsNo response from manufacturer
8Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flawsSep 17, 2020Same property (MITRE EMB3D)PID-3114 shared attributes: Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web ApplicationNo response from manufacturer
9Mira’s cloud login accepted any password and returned a session tokenAug 11, 202613 shared attributesCloud connectivity, User accounts, Remote access, Off-the-shelf software +9No response from manufacturer
10Fresenius Kabi Agilia Connect infusion accessories expose unauthenticated endpoints and weak TLSDec 21, 202111 shared attributesWeb interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application +7No response from manufacturer
11CISA worked through the open-source DICOM stack all yearJun 30, 202612 shared attributesOff-the-shelf software, Cloud connectivity, Web interface, User accounts +8No response from manufacturer
12Ypsomed mylife App and Cloud encrypted traffic with hard-coded secrets and fixed IVsJul 15, 202110 shared attributesData, Cloud, Cloud connectivity, User accounts +6No response from manufacturer
13Dario Health glucose monitoring app and servers exposed cross-user health dataFeb 27, 202510 shared attributesCloud, Data, Cloud connectivity, Web interface +6No response from manufacturer
14CISA spent the summer working through the DICOM stackAug 11, 202610 shared attributesOff-the-shelf software, Web interface, Cloud connectivity, User accounts +6No response from manufacturer
15Five flaws in Sante PACS Server, and one sends credentials in cleartextAug 12, 202511 shared attributesUser accounts, Web interface, Remote access, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +7No response from manufacturer
16Missing authentication on a DNA sequencer control planeOct 21, 202512 shared attributesRemote access, User accounts, Cloud connectivity, Web interface +8No response from manufacturer
17A bundled message broker shipped with guest:guest still enabledMay 29, 202612 shared attributesOff-the-shelf software, User accounts, Remote access, Cloud connectivity +8No response from manufacturer
18Hard-coded credentials and client-side auth in nuclear-medicine softwareDec 2, 202510 shared attributesUser accounts, Remote access, Web interface, Off-the-shelf software +6No response from manufacturer
19Three High Severity Flaws Hit NextGen Healthcare's Mirth ConnectSep 10, 202612 shared attributesOff-the-shelf software, Remote access, User accounts, Cloud connectivity +8No response from manufacturer
20Default credentials across a line of diagnostic instrumentsDec 17, 20249 shared attributesData, Remote access, User accounts, Web interface +5No response from manufacturer

Threats and weaknesses in matched advisories

MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-303 Excessive Trust in Offboard Management/IDE Software TID-304 Manipulate Runtime Environment TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-312 Credential Change Mechanism Can Be Abused TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-315 Password Retrieval Mechanism Abused TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort