Radiography 7000 M
System, X-Ray, Mobile. Attributes come from Philips's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
Attributes: component types
API Battery Display Generic Hardware Local Application Local Service Motor Sensor Modules User Interface Wireless Module
Attributes: interface types
Wireless
Attributes: assets
Patient Data
Attributes: dataflows
RIS/HIS to Radiography 7000 M (patient and exam information) Radiography 7000 M to PACS (digital images) Wireless flat panel detector to Radiography 7000 M (image acquisition)
Matched threat intel
9
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what Philips has said.
| Advisory | Date | Shared | Philips status |
|---|---|---|---|
| Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A hospital management backend leaked its own system information | Oct 28, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A legacy cardiology system, end-of-service since 2014, recalled for security | Jun 10, 2025 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
| GE Healthcare imaging and ultrasound systems expose default service credentials | Dec 8, 2020 | Same property (MITRE EMB3D)PID-411 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-210 Device Vulnerabilities Unpatchable TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-320 SQL Injection TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')