Patient Portal patient engagement platform
Patient engagement image sharing platform. Attributes come from Philips's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-2322 Device deploys an access enforcement/privilege mechanism PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Local Application Local Service Operating System User Interface Web Application
Attributes: assets
Credentials Patient Data
Attributes: dataflows
Patient Portal to EMR portal (integration) Patient Portal to patient browser-enabled devices (images and exam data) Patient to authorized parties (shared images)
Matched threat intel
Top 20 of 28
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Philips has said.
| # | Advisory | Date | Shared | Philips status |
|---|---|---|---|---|
| 1 | A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | Same property (MITRE EMB3D)PID-232212 shared attributes: Imaging family, Handles patient data, Web interface, User accounts +8 | No response from manufacturer |
| 2 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-3117 shared attributes: Patient, Portal, Web interface, Handles patient data +3 | No response from manufacturer |
| 3 | BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | Same property (MITRE EMB3D)PID-3115 shared attributes: User accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application +1 | No response from manufacturer |
| 4 | Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | Same property (MITRE EMB3D)PID-3326 shared attributes: Device includes the usage of a web/HTTP applications (PID-311), Device includes authenticated services (PID-332), Device exposes remote network services (PID-41), Web Application +2 | No response from manufacturer |
| 5 | BD Synapsys sessions did not expire, risking changes to patient data | May 31, 2022 | Same property (MITRE EMB3D)PID-3324 shared attributes: User accounts, Handles patient data, Device includes authenticated services (PID-332), Patient Data | No response from manufacturer |
| 6 | Five flaws in Sante PACS Server, and one sends credentials in cleartext | Aug 12, 2025 | 12 shared attributesImaging family, Image, HL7 or FHIR integration, User accounts +8 | No response from manufacturer |
| 7 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | 11 shared attributesPatient, Portal, Handles patient data, Web interface +7 | No response from manufacturer |
| 8 | Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | 9 shared attributesImaging family, Image, User accounts, Web interface +5 | No response from manufacturer |
| 9 | Pixmeo OsiriX MD crashes on crafted DICOM files and sends web portal credentials in cleartext | May 8, 2025 | 8 shared attributesImaging family, Image, Web interface, User accounts +4 | No response from manufacturer |
| 10 | Stored passwords recoverable in a Siemens imaging platform | Feb 10, 2026 | 8 shared attributesImaging family, Image, User accounts, Role-based access +4 | No response from manufacturer |
| 11 | ZOLL Defibrillator Dashboard lets non-admin users upload files that run commands | Jun 10, 2021 | 6 shared attributesWeb interface, Role-based access, User accounts, Device includes the usage of a web/HTTP applications (PID-311) +2 | No response from manufacturer |
| 12 | Four unpatched flaws disclosed in HAPI FHIR, the server library behind Smile CDR | Oct 22, 2026 | 8 shared attributesPlatform, Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Device includes authenticated services (PID-332) +4 | No response from manufacturer |
| 13 | Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | 7 shared attributesPortal, Web interface, HL7 or FHIR integration, Handles patient data +3 | No response from manufacturer |
| 14 | Philips DoseWise Portal hard-codes its database credentials and stores logins in clear text | Aug 17, 2017 | 7 shared attributesUser accounts, Web interface, Handles patient data, Device includes the usage of a web/HTTP applications (PID-311) +3 | No response from manufacturer |
| 15 | Philips lists EncoreAnywhere and VuePACS as affected by Telerik CVE-2019-18935 deserialization flaw | Dec 9, 2019 | 7 shared attributesImaging family, Portal, Web interface, Handles patient data +3 | No response from manufacturer |
| 16 | Philips lists Focal Point and IntelliSpace Cardiovascular under ASP.NET Core CVE-2025-55315 | Nov 5, 2025 | 6 shared attributesImage, Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311) +2 | No response from manufacturer |
| 17 | OpenClinic GA advisory lists authentication bypass, file upload and SQL abuse flaws | Jul 2, 2020 | 5 shared attributesUser accounts, Role-based access, Web interface, Web Application +1 | No response from manufacturer |
| 18 | Attackers chain two SonicWall SMA1000 flaws into unauthenticated RCE | Sep 4, 2026 | 7 shared attributesDevice exposes remote network services (PID-41), Device includes authenticated services (PID-332), Device includes the usage of a web/HTTP applications (PID-311), Device includes interactive applications, services, or user interfaces (PID-33) +3 | No response from manufacturer |
| 19 | Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flaws | Sep 17, 2020 | 5 shared attributesPlatform, Web interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311) +1 | No response from manufacturer |
| 20 | GE Healthcare ultrasound systems let a local user escape Kiosk Mode to the operating system | Feb 18, 2020 | 6 shared attributesImaging family, User accounts, Operating System, Local Application +2 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-303 Excessive Trust in Offboard Management/IDE Software TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-284 Improper Access Control CWE-294 Authentication Bypass by Capture-replay CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort