HearCare MED-EL
Patient mobile app for remote care. Attributes come from MED-EL's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-23 Device includes OS/kernel PID-2322 Device deploys an access enforcement/privilege mechanism PID-27 Device includes support for firmware/software updates PID-275 Device includes remotely-initiated firmware/software updates PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
iOS companion app: iOS app Android Android 10 Android 11 Android 12 Android 13 Android 14 Android 8 Android 9
Attributes: component types
API Cloud Service Firmware Generic Application Local Application Local Service Mobile Application Operating System Storage User Interface
Attributes: interface types
Bluetooth Cellular TCP WiFi
Attributes: assets
Credentials Report Data Software Configuration User Data
Attributes: dataflows
Clinic to HearCare app (new audio processor configurations via Remote Care) Clinician to HearCare app (older configurations) Clinician to HearCare app (system check requests and questionnaires) HearCare app to Audio Processor (pairing and system checks) HearCare app to Clinic (system check results) HearCare app to MED-EL Cloud (audio processor configuration backup)
Matched threat intel
Top 20 of 80
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what MED-EL has said.
| # | Advisory | Date | Shared | MED-EL status |
|---|---|---|---|---|
| 1 | Empty passwords and cleartext storage in a home cardiac monitor | Jul 24, 2025 | Exposed to the same EMB3D threatTID-31112 shared attributes: Patient, Handles patient data, Home use, User accounts +8 | No response from manufacturer |
| 2 | Default credentials across a line of diagnostic instruments | Dec 17, 2024 | Same property (MITRE EMB3D)PID-3328 shared attributes: Handles patient data, Remote access, User accounts, Wireless connectivity +4 | No response from manufacturer |
| 3 | Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | Exposed to the same EMB3D threatTID-3298 shared attributes: User accounts, Remote access, Handles patient data, Role-based access +4 | No response from manufacturer |
| 4 | Stored passwords recoverable in a Siemens imaging platform | Feb 10, 2026 | Exposed to the same EMB3D threatTID-3298 shared attributes: User accounts, Role-based access, Remote access, Handles patient data +4 | No response from manufacturer |
| 5 | Ossur Logic mobile app shipped hard-coded credentials and a static token in its binary | Dec 19, 2024 | Same property (MITRE EMB3D)PID-3326 shared attributes: Mobile, Mobile app, User accounts, Mobile Application +2 | No response from manufacturer |
| 6 | Philips PageWriter TC cardiographs expose a hard-coded superuser password and unchecked input | Aug 16, 2018 | Exposed to the same EMB3D threatTID-3297 shared attributes: User accounts, Device includes OS/kernel (PID-23), Operating System, Generic Application +3 | No response from manufacturer |
| 7 | Swisslog Translogic Nexus Control Panel ships hard-coded root passwords and unvalidated updates | Aug 3, 2021 | Exposed to the same EMB3D threatTID-3297 shared attributes: User accounts, Field-updatable firmware, Device exposes remote network services (PID-41), Local Service +3 | No response from manufacturer |
| 8 | BIOTRONIK CardioMessenger II-S home monitors store recoverable credentials and leak them in cleartext | Jun 18, 2020 | Same attributes (interface and component types)Cellular, Cloud Service6 shared attributes: Remote access, Home use, Handles patient data, Wireless connectivity +2 | No response from manufacturer |
| 9 | BD Pyxis dispensing and supply systems ship with hard-coded credentials across 24 products | Mar 3, 2022 | Exposed to the same EMB3D threatTID-3295 shared attributes: User accounts, Handles patient data, Generic Application, Storage +1 | No response from manufacturer |
| 10 | BD Alaris 8000 PC unit stores wireless network credentials unencrypted in flash memory | Jan 17, 2017 | Exposed to the same EMB3D threatTID-3294 shared attributes: Care, Wireless connectivity, Storage, Credentials | No response from manufacturer |
| 11 | Hillrom Welch Allyn ELI resting electrocardiographs contain hard-coded passwords | Jun 16, 2022 | Exposed to the same EMB3D threatTID-3293 shared attributes: User accounts, Firmware, Credentials | No response from manufacturer |
| 12 | BD Synapsys sessions did not expire, risking changes to patient data | May 31, 2022 | Same property (MITRE EMB3D)PID-3323 shared attributes: User accounts, Handles patient data, Device includes authenticated services (PID-332) | No response from manufacturer |
| 13 | Medtronic CareLink 9790, 2090 and Encore 29901 programmers store patient data unencrypted | Dec 13, 2018 | Exposed to the same EMB3D threatTID-3293 shared attributes: Handles patient data, Storage, Report Data | No response from manufacturer |
| 14 | Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | 19 shared attributesMobile, Handles patient data, Cloud connectivity, User accounts +15 | No response from manufacturer |
| 15 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | 16 shared attributesRemote access, User accounts, Wireless connectivity, Field-updatable firmware +12 | No response from manufacturer |
| 16 | Flow Neuroscience FL-100 ships a shared Bluetooth credential in every unit | Aug 13, 2026 | 14 shared attributesWireless connectivity, User accounts, Home use, Field-updatable firmware +10 | No response from manufacturer |
| 17 | B. Braun SpaceCom and Battery Pack SP with Wi-Fi carry 11 flaws from XSS to unsigned firmware | Oct 22, 2020 | 12 shared attributesWireless connectivity, Field-updatable firmware, Named operating system, User accounts +8 | No response from manufacturer |
| 18 | Hidden BLE commands can switch off a vagus nerve stimulator’s safety limits | Aug 11, 2026 | 13 shared attributesWireless connectivity, User accounts, Home use, Field-updatable firmware +9 | No response from manufacturer |
| 19 | Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | 14 shared attributesMobile, Wireless connectivity, Handles patient data, User accounts +10 | No response from manufacturer |
| 20 | St. Jude Medical Merlin@home transmitters do not verify the Merlin.net endpoint | Jan 9, 2017 | 9 shared attributesRemote, Cloud connectivity, Remote access, Field-updatable firmware +5 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-108 ROM/NVRAM Data Extraction or Modification TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-303 Excessive Trust in Offboard Management/IDE Software TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort