Aperio eSlide Manager
Digital pathology image management software. Attributes come from Leica Biosystems's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-2322 Device deploys an access enforcement/privilege mechanism PID-27 Device includes support for firmware/software updates PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Attributes: component types
API Firmware Generic Application Library Local Application Local Service Operating System User Interface Web Application
Attributes: interface types
TCP TLS
Attributes: assets
Log Data Patient Data Report Data
Attributes: dataflows
Aperio eSlide Manager to LIS (report images and image analysis results shared into reports) Aperio eSlide Manager to LIS (viewing slides and associated information within the LIS) Aperio eSlide Manager to web viewer or ImageScope (slide images) Hub to spoke servers (multi-site hub and spoke network)
Matched threat intel
Top 20 of 80
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Leica Biosystems has said.
| # | Advisory | Date | Shared | Leica Biosystems status |
|---|---|---|---|---|
| 1 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-41115 shared attributes: Handles patient data, Remote access, User accounts, Cloud connectivity +11 | No response from manufacturer |
| 2 | Mira’s cloud login accepted any password and returned a session token | Aug 11, 2026 | Same property (MITRE EMB3D)PID-41114 shared attributes: Handles patient data, Cloud connectivity, User accounts, Remote access +10 | No response from manufacturer |
| 3 | Compounding software that did not encrypt its database traffic by default | May 15, 2026 | Same property (MITRE EMB3D)PID-411313 shared attributes: Patient or study database, Handles patient data, Remote access, User accounts +9 | No response from manufacturer |
| 4 | Default credentials across a line of diagnostic instruments | Dec 17, 2024 | Same property (MITRE EMB3D)PID-33210 shared attributes: Handles patient data, Remote access, User accounts, Web interface +6 | No response from manufacturer |
| 5 | Medtronic MyCareLink 24950 and 24952 monitors store upload credentials in a recoverable format | Aug 7, 2018 | Same property (MITRE EMB3D)PID-41134 shared attributes: Cloud connectivity, Handles patient data, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), Patient Data | No response from manufacturer |
| 6 | Medtronic CareLink 9790, 2090 and Encore 29901 programmers store patient data unencrypted | Dec 13, 2018 | Exposed to the same EMB3D threatTID-2213 shared attributes: Handles patient data, Patient Data, Report Data | No response from manufacturer |
| 7 | A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | 18 shared attributesImaging family, Handles patient data, Web interface, User accounts +14 | No response from manufacturer |
| 8 | Five flaws in Sante PACS Server, and one sends credentials in cleartext | Aug 12, 2025 | 18 shared attributesImaging family, Image, HL7 or FHIR integration, User accounts +14 | No response from manufacturer |
| 9 | CISA worked through the open-source DICOM stack all year | Jun 30, 2026 | 15 shared attributesImaging family, Image, Cloud connectivity, Web interface +11 | No response from manufacturer |
| 10 | Three High Severity Flaws Hit NextGen Healthcare's Mirth Connect | Sep 10, 2026 | 17 shared attributesHandles patient data, Remote access, User accounts, Patient or study database +13 | No response from manufacturer |
| 11 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | 14 shared attributesPatient or study database, Handles patient data, Cloud connectivity, Web interface +10 | No response from manufacturer |
| 12 | CISA spent the summer working through the DICOM stack | Aug 11, 2026 | 12 shared attributesImaging family, Image, Web interface, Cloud connectivity +8 | No response from manufacturer |
| 13 | Unauthenticated SQL injection into an imaging database, base score 9.8 | Dec 6, 2024 | 15 shared attributesImaging family, Patient or study database, Handles patient data, Remote access +11 | No response from manufacturer |
| 14 | Stored passwords recoverable in a Siemens imaging platform | Feb 10, 2026 | 12 shared attributesImaging family, Image, User accounts, Role-based access +8 | No response from manufacturer |
| 15 | An open-source DICOM server that shipped with auth off by default | Feb 6, 2025 | 14 shared attributesImaging family, Handles patient data, Remote access, User accounts +10 | No response from manufacturer |
| 16 | A bundled message broker shipped with guest:guest still enabled | May 29, 2026 | 15 shared attributesDigital, Pathology, User accounts, Remote access +11 | No response from manufacturer |
| 17 | Nine CVEs in Orthanc, and the image decoder is the soft spot | Apr 9, 2026 | 14 shared attributesImaging family, Remote access, Patient or study database, Handles patient data +10 | No response from manufacturer |
| 18 | Hard-coded credentials and client-side auth in nuclear-medicine software | Dec 2, 2025 | 12 shared attributesUser accounts, Remote access, Web interface, Role-based access +8 | No response from manufacturer |
| 19 | Unrestricted file upload on a PACS points straight at code execution | Apr 10, 2025 | 13 shared attributesImaging family, Patient or study database, Web interface, Remote access +9 | No response from manufacturer |
| 20 | Fresenius Kabi Agilia Connect infusion accessories expose unauthenticated endpoints and weak TLS | Dec 21, 2021 | 11 shared attributesWeb interface, Hospital network, User accounts, Device includes the usage of a web/HTTP applications (PID-311) +7 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-116 Latent Privileged Access Port TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-303 Excessive Trust in Offboard Management/IDE Software TID-304 Manipulate Runtime Environment TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort