NovaSeq 6000Dx Instrument
IVD high-throughput sequencing instrument. Attributes come from Illumina's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-11 Device includes a microprocessor PID-12 Device includes Memory/Storage (external to CPU) PID-124 Device includes Random Access Memory (RAM) chips PID-1241 Device includes DDR DRAM PID-23 Device includes OS/kernel PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-34 Device stores logs of application events and information PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
Windows 10
Attributes: materials
Windows 10
Attributes: component types
API CPU Cloud Service Display Generic Application Generic Hardware Local Application Local Service Memory Operating System Storage User Interface
Attributes: interface types
RFID TCP
Attributes: assets
Log Data Patient Data Software Configuration User Data
Attributes: dataflows
Instrument to remote user via Illumina Run Manager (run progress and instrument control) Sequencer to paired DRAGEN Server for secondary analysis Stand-alone DRAGEN Server to BaseSpace Sequence Hub (RUO applications)
Matched threat intel
Top 20 of 39
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Illumina has said.
| # | Advisory | Date | Shared | Illumina status |
|---|---|---|---|---|
| 1 | Cepheid GeneXpert Xpress 6.4a ships without Windows speculative execution mitigations | Mar 11, 2026 | Same named componentWindows 10 (= 21H2 / 22H2)6 shared attributes: Lab and diagnostics family, Named operating system, Device includes OS/kernel (PID-23), Operating System +2 | No response from manufacturer |
| 2 | Philips lists more than 30 products in DejaBlue Remote Desktop advisory | Aug 15, 2019 | Same named componentWindows 10 (= 1703)7 shared attributes: Named operating system, Remote access, Device includes OS/kernel (PID-23), Device exposes remote network services (PID-41) +3 | No response from manufacturer |
| 3 | Carestream DirectView and ImageView systems affected by BlueKeep and DejaBlue RDP flaws | May 16, 2019 | Same named componentWindows 10 (= 1607 LTSB)7 shared attributes: Named operating system, Remote access, Device includes OS/kernel (PID-23), Device exposes remote network services (PID-41) +3 | No response from manufacturer |
| 4 | Siemens Healthineers lists imaging and lab products affected by DejaBlue Remote Desktop flaws | Sep 10, 2019 | Same named componentWindows 10 (= 1703)6 shared attributes: Lab and diagnostics family, Named operating system, Remote access, Operating System +2 | No response from manufacturer |
| 5 | BD lists Pyxis, Alaris and lab systems in scope for DejaBlue Remote Desktop flaws | Oct 30, 2019 | Same named componentWindows 10 (= 1703)6 shared attributes: Lab and diagnostics family, Remote access, Named operating system, Operating System +2 | No response from manufacturer |
| 6 | Cepheid GeneXpert Dx 6.4a needs Windows 10 update KB5068781 for 32 CVEs | Mar 12, 2026 | Same named componentWindows 10 (= 21H2)5 shared attributes: Lab and diagnostics family, Named operating system, Device includes OS/kernel (PID-23), Operating System +1 | No response from manufacturer |
| 7 | Philips reviews 70 products for Windows RD Gateway and Remote Desktop Client flaws | Jan 15, 2020 | Same named componentWindows 10 (= 1803)6 shared attributes: Named operating system, Remote access, Operating System, Local Service +2 | No response from manufacturer |
| 8 | BD lists FocalPoint, Kiestra and BD MAX in scope for three Remote Desktop flaws | Apr 3, 2020 | Same named componentWindows 10 (= 1803)5 shared attributes: Lab and diagnostics family, Remote access, Operating System, Local Service +1 | No response from manufacturer |
| 9 | BD lists FACS, Pyxis and Kiestra products in scope for Win32k zero-day CVE-2021-1732 | Jul 29, 2021 | Same named componentWindows 10 (= 1803)4 shared attributes: Lab and diagnostics family, Named operating system, Operating System, Local Application | No response from manufacturer |
| 10 | Carestream lists Windows 10 based imaging products as affected by CurveBall CryptoAPI flaw | Jan 17, 2020 | Same named componentWindows 10 (any version)4 shared attributes: Named operating system, Device includes OS/kernel (PID-23), Operating System, Local Application | No response from manufacturer |
| 11 | BD tests Microsoft's Bad Neighbor patch for FACS, Pyxis and Rowa products | Dec 3, 2020 | Same named componentWindows 10 (= 1803)3 shared attributes: Lab and diagnostics family, Named operating system, Operating System | No response from manufacturer |
| 12 | Philips names ten product lines in Windows Task Scheduler CVE-2024-49039 notice | Nov 18, 2024 | Same named componentWindows 10 (= 1809)2 shared attributes: Named operating system, Operating System | No response from manufacturer |
| 13 | Philips lists Corsium and IntelliSpace PACS in Windows downgrade attack notice | Sep 20, 2024 | Same named componentWindows 10 (range 1809 10.0.17763.0)2 shared attributes: Named operating system, Operating System | No response from manufacturer |
| 14 | Philips lists IntelliSpace PACS, UroNav and PICiX under Windows RPC flaws CVE-2023-21708 and CVE-2023-23405 | Mar 22, 2023 | Same named componentWindows 10 (range 10.0.0)2 shared attributes: Named operating system, Operating System | No response from manufacturer |
| 15 | Philips lists 26 products running Windows under the CryptoAPI spoofing flaw CVE-2020-0601 | Jan 16, 2020 | Same named componentWindows 10 (= 1803)2 shared attributes: Named operating system, Operating System | No response from manufacturer |
| 16 | BD tests Microsoft fix for CryptoAPI spoofing flaw CVE-2020-0601 | Jan 31, 2020 | Same named componentWindows 10 (= 1803)1 shared attribute: Operating System | No response from manufacturer |
| 17 | Canon Medical says CT, MR, VL and XR systems may be exposed to RPC runtime flaw CVE-2022-26809 | Jul 4, 2022 | Same named componentWindows 10 (range 10.0.0)1 shared attribute: TCP | No response from manufacturer |
| 18 | Philips lists Capsule Neuron under Windows PEAP denial of service CVE-2023-21701 | Mar 29, 2023 | Same named componentWindows 10 (range 10.0.0) | No response from manufacturer |
| 19 | BD Pyxis products may still run on shared default operating system credentials | May 31, 2022 | Same property (MITRE EMB3D)PID-237 shared attributes: User accounts, Device includes OS/kernel (PID-23), Operating System, Generic Hardware +3 | No response from manufacturer |
| 20 | Thermo Fisher Xcalibur and Foundation driver packages allow local privilege escalation | Jan 22, 2025 | Same platformWindows3 shared attributes: Instrument, Named operating system, Local Application | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-216 Firmware Update Rollbacks Allowed TID-219 OS/Kernel Privilege Escalation TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-345 Insufficient Verification of Data Authenticity CWE-427 Uncontrolled Search Path Element CWE-494 Download of Code Without Integrity Check CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials