PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Attributes: component types
Circuit Board Display Library Local Application Local Service Storage User Interface
Attributes: interface types
Ethernet Serial USB
Attributes: assets
Credentials Patient Data
Attributes: dataflows
Analyzer to LIS over bidirectional Ethernet/RS-232 interface Analyzer to USB external storage Analyzer to USB printer
Matched threat intel
Top 20 of 30
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Beckman Coulter has said.
| # | Advisory | Date | Shared | Beckman Coulter status |
|---|---|---|---|---|
| 1 | Default credentials across a line of diagnostic instruments | Dec 17, 2024 | Same property (MITRE EMB3D)PID-3329 shared attributes: Lab and diagnostics family, Handles patient data, Wired network, User accounts +5 | No response from manufacturer |
| 2 | Compounding software that did not encrypt its database traffic by default | May 15, 2026 | Same property (MITRE EMB3D)PID-41139 shared attributes: Patient or study database, Handles patient data, Wired network, User accounts +5 | No response from manufacturer |
| 3 | Philips Alice 6 through R8.0.3 lacks authentication and encryption between nodes | Mar 27, 2018 | Exposed to the same EMB3D threatTID-4116 shared attributes: Wired network, User accounts, Handles patient data, Hospital network +2 | No response from manufacturer |
| 4 | Philips Interoperability Solution XDS can expose LDAP system credentials in cleartext | Jun 24, 2021 | Exposed to the same EMB3D threatTID-4116 shared attributes: User accounts, Hospital network, Wired network, Device exposes remote network services (PID-41) +2 | No response from manufacturer |
| 5 | Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | Same property (MITRE EMB3D)PID-41137 shared attributes: Hospital network, Handles patient data, Wired network, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +3 | No response from manufacturer |
| 6 | Medtronic CareLink 9790, 2090 and Encore 29901 programmers store patient data unencrypted | Dec 13, 2018 | Exposed to the same EMB3D threatTID-2213 shared attributes: Handles patient data, Storage, Patient Data | No response from manufacturer |
| 7 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | 10 shared attributesLab and diagnostics family, Handles patient data, User accounts, Patient or study database +6 | No response from manufacturer |
| 8 | Baxter ExactaMix compounders carry hard-coded admin credentials and send orders in clear text | Jun 18, 2020 | 11 shared attributesUser accounts, USB port, Patient or study database, Handles patient data +7 | No response from manufacturer |
| 9 | Two maximum-severity flaws in a ventilation system | Nov 14, 2024 | 8 shared attributesUser accounts, Wired network, USB port, Serial interface +4 | No response from manufacturer |
| 10 | Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interface | Nov 6, 2018 | 8 shared attributesLab and diagnostics family, Analyzer, Wired network, Hospital network +4 | No response from manufacturer |
| 11 | BD Totalys MultiProcessor 1.70 and earlier uses hard-coded credentials | Oct 4, 2022 | 7 shared attributesLab and diagnostics family, User accounts, Handles patient data, Hospital network +3 | No response from manufacturer |
| 12 | BD FACSChorus workstations leave USB, BIOS and PCIe open and store admin secrets in plaintext | Nov 27, 2023 | 6 shared attributesLab and diagnostics family, USB port, Patient or study database, User accounts +2 | No response from manufacturer |
| 13 | BD Pyxis products may still run on shared default operating system credentials | May 31, 2022 | 7 shared attributesUser accounts, Handles patient data, Hospital network, Wired network +3 | No response from manufacturer |
| 14 | BD Kiestra lab automation lets privileged accounts issue SQL commands that can corrupt data | May 22, 2018 | 8 shared attributesLab and diagnostics family, Patient or study database, Handles patient data, Local Application +4 | No response from manufacturer |
| 15 | BD Kiestra TLA, WCA and InoqulA+ database open through SMB1 and default credentials | May 16, 2017 | 8 shared attributesLab and diagnostics family, Patient or study database, Handles patient data, Device exposes remote network services (PID-41) +4 | No response from manufacturer |
| 16 | Capsule Technologies SmartLinx Neuron 2 kiosk escapes to admin with a USB keyboard | Jul 14, 2020 | 6 shared attributesUSB port, Hospital network, Device includes external peripheral interconnects (e.g., USB, Serial) (PID-14), User Interface +2 | No response from manufacturer |
| 17 | GE Aestiva and Aespire anesthesia devices can have alarms silenced through unsecured terminal servers | Jul 9, 2019 | 4 shared attributesSerial interface, Wired network, Device includes external peripheral interconnects (e.g., USB, Serial) (PID-14), Serial | No response from manufacturer |
| 18 | Baxter Welch Allyn Configuration Tool put entered credentials at risk | May 30, 2024 | 5 shared attributesUser accounts, Hospital network, Device includes authenticated services (PID-332), Local Application +1 | No response from manufacturer |
| 19 | BD Kiestra PerformA and KLA Journal Service use a hard-coded database password | Mar 23, 2017 | 5 shared attributesLab and diagnostics family, Patient or study database, Handles patient data, Credentials +1 | No response from manufacturer |
| 20 | BD Pyxis dispensing and supply systems ship with hard-coded credentials across 24 products | Mar 3, 2022 | 5 shared attributesUser accounts, Handles patient data, Storage, Credentials +1 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-107 Unauthorized Direct Memory Access (DMA) TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-213 Faulty FW/SW Update Integrity Verification TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-476 NULL Pointer Dereference CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort