Cardio Server ECG Management System
ECG management software. Attributes come from Baxter's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-27 Device includes support for firmware/software updates PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
Android iOS Windows
Attributes: materials
Windows Server
Attributes: component types
API Cloud Service Firmware Generic Application Local Application Local Service User Interface Web Application
Attributes: interface types
TCP Unknown
Attributes: assets
Patient Data Report Data Software Update User Data
Attributes: dataflows
Baxter ELI ECG devices to Cardio Server (Device Report) Cardio Server to Cardiographs and modality devices (demographic and order information via modality worklist) Cardio Server to EMR (confirmed ECG results) Cardiographs to Cardio Server (ECG interpretations and measurements) Remote user to Cardio Server via VPN iOS/Android device to Cardio Server over web (view, edit and confirm ECGs)
Matched threat intel
Top 20 of 161
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Baxter has said.
| # | Advisory | Date | Shared | Baxter status |
|---|---|---|---|---|
| 1 | BD Pyxis keeps access for expired Active Directory accounts when joined to a hospital domain | Sep 5, 2019 | Same named componentWindows Server (range 4.4)10 shared attributes: Server, User accounts, Hospital network, Handles patient data +6 | No response from manufacturer |
| 2 | Philips’ July advisory run is a lesson in where device risk actually lives | Aug 11, 2026 | Same named componentWindows Server (range 10.0.20348.0)8 shared attributes: Cardiology and implants family, Off-the-shelf software, Named operating system, Remote access +4 | No response from manufacturer |
| 3 | Philips names ten product lines in Windows Task Scheduler CVE-2024-49039 notice | Nov 18, 2024 | Same named componentWindows Server (= 2019)6 shared attributes: Cardiology and implants family, Named operating system, Off-the-shelf software, Hospital network +2 | No response from manufacturer |
| 4 | Philips lists more than 30 products in DejaBlue Remote Desktop advisory | Aug 15, 2019 | Same named componentWindows Server (= 1803)8 shared attributes: Cardiology and implants family, Server, Named operating system, Remote access +4 | No response from manufacturer |
| 5 | Philips names PACS and imaging servers in Zerologon CVE-2020-1472 advisory | Sep 14, 2020 | Same named componentWindows Server (= 1903)7 shared attributes: Cardiology and implants family, Server, Named operating system, Hospital network +3 | No response from manufacturer |
| 6 | Spacelabs Xhibit Telemetry Receiver is exposed to the BlueKeep RDP flaw | Feb 18, 2020 | Same named componentWindows Server (= 2003)8 shared attributes: Named operating system, Remote access, Off-the-shelf software, Physiological waveform processing +4 | No response from manufacturer |
| 7 | Philips lists PIC iX and Focal Point under exploited WSUS flaw CVE-2025-59287 | Oct 27, 2025 | Same named componentWindows Server (= 2012)5 shared attributes: Named operating system, Field-updatable firmware, Hospital network, Local Service +1 | No response from manufacturer |
| 8 | Philips IntelliSpace Portal 7.0 and 8.0 carry 35 vulnerabilities, led by remote code execution | Feb 27, 2018 | Same named componentWindows Server (= 2008 R2 SP1)8 shared attributes: Named operating system, Remote access, Hospital network, Off-the-shelf software +4 | No response from manufacturer |
| 9 | Carestream lists Windows 10 based imaging products as affected by CurveBall CryptoAPI flaw | Jan 17, 2020 | Same named componentWindows Server (= 2016)4 shared attributes: Named operating system, Local Application, Software Update, Windows Server | No response from manufacturer |
| 10 | Philips lists HeartStart, IntelliVue and IntelliSpace products as Windows Server 2012 reaches end of life | Oct 10, 2023 | Same named componentWindows Server (= 2012)3 shared attributes: Cardiology and implants family, Named operating system, Windows Server | No response from manufacturer |
| 11 | Philips reviews 52 products running Windows 7 and Server 2008 R2 at end of support | Jan 14, 2020 | Same named componentWindows Server (= 2008 R2)3 shared attributes: Cardiology and implants family, Named operating system, Windows Server | No response from manufacturer |
| 12 | Philips lists 26 products running Windows under the CryptoAPI spoofing flaw CVE-2020-0601 | Jan 16, 2020 | Same named componentWindows Server (= 1803)4 shared attributes: Cardiology and implants family, Named operating system, Off-the-shelf software, Software Update | No response from manufacturer |
| 13 | Beckman Coulter validates Microsoft's BlueKeep patch across its Windows systems | Jun 28, 2019 | Same named componentWindows Server (= 2003)4 shared attributes: Named operating system, Local Service, TCP, Windows Server | No response from manufacturer |
| 14 | BD lists Pyxis, Alaris and lab systems in scope for DejaBlue Remote Desktop flaws | Oct 30, 2019 | Same named componentWindows Server (= 1803)5 shared attributes: Server, Remote access, Named operating system, Local Service +1 | No response from manufacturer |
| 15 | Biosense Webster CARTO 3 V6 SP3 applies Windows patches and antivirus updates | Jan 8, 2021 | Same named componentWindows Server (= 2008 R2 SP1)4 shared attributes: Cardiology and implants family, Named operating system, Local Application, Software Update | No response from manufacturer |
| 16 | BD lists FACS, Pyxis and Kiestra products in scope for Win32k zero-day CVE-2021-1732 | Jul 29, 2021 | Same named componentWindows Server (= 1909)3 shared attributes: Named operating system, Local Application, Windows Server | No response from manufacturer |
| 17 | Philips lists Azurion, EPIQ and Affiniti under Windows IPv6 flaw CVE-2024-38063 | Aug 30, 2024 | Same named componentWindows Server (range 10.0.17763.0)4 shared attributes: Named operating system, Hospital network, TCP, Software Update | No response from manufacturer |
| 18 | bioMérieux tells Windows 10 system users to install CryptoAPI fix for CVE-2020-0601 | Oct 14, 2020 | Same named componentWindows Server (= 2016)2 shared attributes: Named operating system, Windows Server | No response from manufacturer |
| 19 | Siemens Healthineers lists imaging and lab products affected by DejaBlue Remote Desktop flaws | Sep 10, 2019 | Same named componentWindows Server (= 1803)5 shared attributes: Named operating system, Hospital network, Remote access, Local Service +1 | No response from manufacturer |
| 20 | Philips lists PACS, PIC iX and IntelliBridge products as exposed to the SIGRED Windows DNS flaw | Jul 15, 2020 | Same named componentWindows Server (= 1903)4 shared attributes: Named operating system, Off-the-shelf software, Local Service, TCP | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-116 Latent Privileged Access Port TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-216 Firmware Update Rollbacks Allowed TID-217 Remotely Initiated Updates Can Cause DoS TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-303 Excessive Trust in Offboard Management/IDE Software TID-304 Manipulate Runtime Environment TID-305 Program Executes Dangerous System Calls TID-306 Sandboxed Environments Escaped TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-318 Insecure Cryptographic Implementation TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-353 Missing Support for Integrity Check CWE-400 Uncontrolled Resource Consumption CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-476 NULL Pointer Dereference CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort