Silent ICU
ICU alarm management solution. Attributes come from Ascom's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
Attributes: component types
Generic Application Library Local Application Local Service Mobile Application User Interface
Attributes: interface types
TCP TLS
Attributes: assets
Telemetry Data
Attributes: dataflows
Alarm system to caregiver mobile devices (actionable alarms routed to the right caregiver) Alarm system to central dashboards (alarm visualization) Alarm to backup team member (redirection when caregiver unavailable) Medical devices to Ascom-distributed alarm system (alarms via ISO/IEEE 11073 SDC)
Matched threat intel
7
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Ascom has said.
| # | Advisory | Date | Shared | Ascom status |
|---|---|---|---|---|
| 1 | Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | Same property (MITRE EMB3D)PID-41136 shared attributes: Patient monitoring family, Hospital network, Wired network, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113) +2 | No response from manufacturer |
| 2 | Philips lists MR, SPECT, ultrasound and telemetry products in Urgent/11 VxWorks advisory | Aug 1, 2019 | 6 shared attributesPatient monitoring family, Wired network, Hospital network, Library +2 | No response from manufacturer |
| 3 | Philips lists IntelliSpace Perinatal and consumer products under NAME:WRECK DNS flaws | Apr 15, 2021 | 4 shared attributesPatient monitoring family, Wired network, Library, TCP | No response from manufacturer |
| 4 | Philips checked its NetScaler exposure the week the exploit went live | Aug 18, 2026 | 3 shared attributesDevice includes procedure to forward or route network messages (PID-42), Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), TCP | No response from manufacturer |
| 5 | Philips lists Focal Point v2.1 under IngressNightmare Kubernetes flaws | Mar 27, 2025 | 4 shared attributesPatient monitoring family, Alarm, Hospital network, TCP | No response from manufacturer |
| 6 | Forescout finds just 6 percent of connected medical devices ready for quantum-safe encryption | Oct 8, 2026 | 3 shared attributesDevice includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), TCP, TLS | No response from manufacturer |
| 7 | OpenAI’s models broke into Hugging Face on their own. Underneath is a pentest harness | Sep 1, 2026 | 3 shared attributesDevice includes procedure to forward or route network messages (PID-42), Local Service, TCP | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-210 Device Vulnerabilities Unpatchable TID-222 Critical System Service May Be Disabled TID-310 Remotely Accessible Unauthenticated Services TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-319 Cross Site Scripting (XSS) TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol