Zeiss Atlas 500
Corneal topographer and dry eye analyzer. Attributes come from ZEISS Medical Technology's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-23 Device includes OS/kernel PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Platform
Windows 10
Attributes: materials
Windows 10
Attributes: component types
API CPU Circuit Board Display Generic Application Generic Hardware Local Application Local Service Memory Operating System Storage User Interface
Attributes: interface types
DisplayPort Ethernet Serial USB
Attributes: assets
Patient Data Report Data
Attributes: dataflows
ATLAS 500 acquisition and analysis suite to ZEISS FORUM (patient data entered on ATLAS 500) ATLAS 500 to ZEISS FORUM (patient data and PDF reports) ATLAS 9000 to ATLAS 500 (data import) ZEISS FORUM to ATLAS 500 (patient scheduling via modality worklists)
Matched threat intel
Top 20 of 39
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what ZEISS Medical Technology has said.
| # | Advisory | Date | Shared | ZEISS Medical Technology status |
|---|---|---|---|---|
| 1 | Cepheid GeneXpert Dx 6.4a needs Windows 10 update KB5068781 for 32 CVEs | Mar 12, 2026 | Same named componentWindows 10 (= 21H2)6 shared attributes: Lab and diagnostics family, Named operating system, Hospital network, Device includes OS/kernel (PID-23) +2 | No response from manufacturer |
| 2 | Philips lists more than 30 products in DejaBlue Remote Desktop advisory | Aug 15, 2019 | Same named componentWindows 10 (= 1703)7 shared attributes: Named operating system, Remote access, Hospital network, Device includes OS/kernel (PID-23) +3 | No response from manufacturer |
| 3 | Carestream DirectView and ImageView systems affected by BlueKeep and DejaBlue RDP flaws | May 16, 2019 | Same named componentWindows 10 (= 1607 LTSB)7 shared attributes: Named operating system, Remote access, Hospital network, Device includes OS/kernel (PID-23) +3 | No response from manufacturer |
| 4 | Siemens Healthineers lists imaging and lab products affected by DejaBlue Remote Desktop flaws | Sep 10, 2019 | Same named componentWindows 10 (= 1703)6 shared attributes: Lab and diagnostics family, Named operating system, Hospital network, Remote access +2 | No response from manufacturer |
| 5 | BD lists Pyxis, Alaris and lab systems in scope for DejaBlue Remote Desktop flaws | Oct 30, 2019 | Same named componentWindows 10 (= 1703)5 shared attributes: Lab and diagnostics family, Remote access, Named operating system, Operating System +1 | No response from manufacturer |
| 6 | Carestream lists Windows 10 based imaging products as affected by CurveBall CryptoAPI flaw | Jan 17, 2020 | Same named componentWindows 10 (any version)4 shared attributes: Named operating system, Device includes OS/kernel (PID-23), Operating System, Local Application | No response from manufacturer |
| 7 | BD tests Microsoft's Bad Neighbor patch for FACS, Pyxis and Rowa products | Dec 3, 2020 | Same named componentWindows 10 (= 1803)3 shared attributes: Lab and diagnostics family, Named operating system, Operating System | No response from manufacturer |
| 8 | Philips reviews 70 products for Windows RD Gateway and Remote Desktop Client flaws | Jan 15, 2020 | Same named componentWindows 10 (= 1803)5 shared attributes: Named operating system, Remote access, Operating System, Local Service +1 | No response from manufacturer |
| 9 | BD lists FocalPoint, Kiestra and BD MAX in scope for three Remote Desktop flaws | Apr 3, 2020 | Same named componentWindows 10 (= 1803)4 shared attributes: Lab and diagnostics family, Remote access, Operating System, Local Service | No response from manufacturer |
| 10 | Philips lists IntelliSpace PACS, UroNav and PICiX under Windows RPC flaws CVE-2023-21708 and CVE-2023-23405 | Mar 22, 2023 | Same named componentWindows 10 (range 10.0.0)3 shared attributes: Named operating system, Wired network, Operating System | No response from manufacturer |
| 11 | Philips lists Corsium and IntelliSpace PACS in Windows downgrade attack notice | Sep 20, 2024 | Same named componentWindows 10 (range 1809 10.0.17763.0)2 shared attributes: Named operating system, Operating System | No response from manufacturer |
| 12 | Philips lists 26 products running Windows under the CryptoAPI spoofing flaw CVE-2020-0601 | Jan 16, 2020 | Same named componentWindows 10 (= 1803)2 shared attributes: Named operating system, Operating System | No response from manufacturer |
| 13 | Philips lists Capsule Neuron under Windows PEAP denial of service CVE-2023-21701 | Mar 29, 2023 | Same named componentWindows 10 (range 10.0.0) | No response from manufacturer |
| 14 | Canon Medical says CT, MR, VL and XR systems may be exposed to RPC runtime flaw CVE-2022-26809 | Jul 4, 2022 | Same named componentWindows 10 (range 10.0.0) | No response from manufacturer |
| 15 | DNA analyzer output could be tampered with, and the software would not notice | Aug 4, 2026 | 11 shared attributesLab and diagnostics family, Analyzer, File import, Patient or study database +7 | No response from manufacturer |
| 16 | Capsule Technologies SmartLinx Neuron 2 kiosk escapes to admin with a USB keyboard | Jul 14, 2020 | 8 shared attributesUSB port, Hospital network, Device includes external peripheral interconnects (e.g., USB, Serial) (PID-14), Device includes OS/kernel (PID-23) +4 | No response from manufacturer |
| 17 | Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interface | Nov 6, 2018 | 8 shared attributesLab and diagnostics family, Analyzer, Wired network, Hospital network +4 | No response from manufacturer |
| 18 | Cepheid GeneXpert Xpress 6.4a ships without Windows speculative execution mitigations | Mar 11, 2026 | 6 shared attributesLab and diagnostics family, Named operating system, Device includes OS/kernel (PID-23), Operating System +2 | No response from manufacturer |
| 19 | A legacy cardiology system, end-of-service since 2014, recalled for security | Jun 10, 2025 | 10 shared attributesPatient or study database, Handles patient data, Remote access, Hospital network +6 | No response from manufacturer |
| 20 | Cepheid tells GeneXpert Dx 6.4a sites to switch off TLS 1.0 and TLS 1.1 | Mar 12, 2026 | 9 shared attributesLab and diagnostics family, Wired network, Named operating system, Hospital network +5 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-103 Microarchitectural Side Channels TID-107 Unauthorized Direct Memory Access (DMA) TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-216 Firmware Update Rollbacks Allowed TID-219 OS/Kernel Privilege Escalation TID-222 Critical System Service May Be Disabled TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-302 Install Untrusted Application TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-319 Cleartext Transmission of Sensitive Information CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-353 Missing Support for Integrity Check CWE-427 Uncontrolled Search Path Element CWE-494 Download of Code Without Integrity Check CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials