navify Digital Pathology
Digital pathology software system. Attributes come from Roche's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-27 Device includes support for firmware/software updates PID-28 Device stores logs of system events and information PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-34 Device stores logs of application events and information PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations PID-4113 Device includes cryptographic functions for sensitive data, such as encryption or authentication
Attributes: component types
API Cloud Application Cloud Service Display Firmware Generic Application Generic Hardware Library Local Application Local Service Operating System User Interface Web Application
Attributes: interface types
Unknown
Attributes: assets
Log Data Model Data Patient Data Report Data User Data
Attributes: dataflows
VENTANA slide scanner to Roche uPath enterprise software (digital images of scanned glass slides) VENTANA slide scanners to navify Digital Pathology navify Digital Pathology to Amazon S3 (image storage)
Matched threat intel
Top 20 of 29
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Roche has said.
| # | Advisory | Date | Shared | Roche status |
|---|---|---|---|---|
| 1 | Philips DoseWise Portal hard-codes its database credentials and stores logins in clear text | Aug 17, 2017 | Same property (MITRE EMB3D)PID-3326 shared attributes: Patient or study database, User accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311) +2 | No response from manufacturer |
| 2 | Philips Tasy EMR HTML5 has two SQL injection flaws that expose patient data | Nov 4, 2021 | Same property (MITRE EMB3D)PID-3325 shared attributes: Patient or study database, User accounts, Web interface, Web Application +1 | No response from manufacturer |
| 3 | BD Alaris Infusion Central leaves a recoverable database password after installation | Feb 16, 2023 | Exposed to the same EMB3D threatTID-2216 shared attributes: Patient or study database, User accounts, Hospital network, Local Application +2 | No response from manufacturer |
| 4 | Medtronic MyCareLink 24950 and 24952 monitors store upload credentials in a recoverable format | Aug 7, 2018 | Same property (MITRE EMB3D)PID-41134 shared attributes: Cloud connectivity, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), Cloud Service, Patient Data | No response from manufacturer |
| 5 | A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | 17 shared attributesWeb interface, User accounts, Cloud connectivity, Remote access +13 | No response from manufacturer |
| 6 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | 12 shared attributesCloud connectivity, User accounts, Web interface, Remote access +8 | No response from manufacturer |
| 7 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | 13 shared attributesPatient or study database, Cloud connectivity, Web interface, User accounts +9 | No response from manufacturer |
| 8 | A hospital management backend leaked its own system information | Oct 28, 2025 | 12 shared attributesRemote access, User accounts, Cloud connectivity, Web interface +8 | No response from manufacturer |
| 9 | Cl0p lists Philips among nearly 50 victims of its PTC Windchill campaign | Aug 14, 2026 | 13 shared attributesCloud connectivity, User accounts, Remote access, Web interface +9 | No response from manufacturer |
| 10 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | 13 shared attributesRemote access, User accounts, Cloud connectivity, Web interface +9 | No response from manufacturer |
| 11 | Unauthenticated SQL injection into an imaging database, base score 9.8 | Dec 6, 2024 | 13 shared attributesPatient or study database, Remote access, Web interface, User accounts +9 | No response from manufacturer |
| 12 | BridgeLink 26.9.0 closes the Mirth Connect flaws CISA flagged, plus eight inherited CVEs | Oct 1, 2026 | 11 shared attributesApplication-level software is present and running on the device (PID-31), Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Device includes authenticated services (PID-332) +7 | No response from manufacturer |
| 13 | Silex modules in GE MobileLink allow unauthenticated setting changes and command injection | May 8, 2018 | 8 shared attributesWeb interface, User accounts, Hospital network, Device includes the usage of a web/HTTP applications (PID-311) +4 | No response from manufacturer |
| 14 | Philips IntelliVue monitors and PIC iX skip certificate revocation and crash on bad input | Sep 10, 2020 | 10 shared attributesHospital network, Web interface, Device includes cryptographic functions for sensitive data, such as encryption or authentication (PID-4113), Device includes the usage of a web/HTTP applications (PID-311) +6 | No response from manufacturer |
| 15 | DNA analyzer output could be tampered with, and the software would not notice | Aug 4, 2026 | 10 shared attributesPatient or study database, Hospital network, User accounts, Device stores logs of system events and information (PID-28) +6 | No response from manufacturer |
| 16 | Philips IntelliBridge Enterprise writes plaintext EMR credentials into its transaction logs | Jun 11, 2020 | 7 shared attributesUser accounts, Web interface, Hospital network, Device stores logs of application events and information (PID-34) +3 | No response from manufacturer |
| 17 | Citrix patches two critical NetScaler zero days after Dutch hospitals shut systems down | Sep 27, 2026 | 9 shared attributesDevice exposes remote network services (PID-41), Device includes the usage of a web/HTTP applications (PID-311), Device stores logs of system events and information (PID-28), Device includes support for firmware/software updates (PID-27) +5 | No response from manufacturer |
| 18 | Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | 9 shared attributesDevice includes the usage of a web/HTTP applications (PID-311), Device includes authenticated services (PID-332), Application-level software is present and running on the device (PID-31), Device exposes remote network services (PID-41) +5 | No response from manufacturer |
| 19 | Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | 7 shared attributesWeb interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application +3 | No response from manufacturer |
| 20 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | 7 shared attributesWeb interface, Cloud connectivity, Patient or study database, Device includes the usage of a web/HTTP applications (PID-311) +3 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-304 Manipulate Runtime Environment TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-20 Improper Input Validation CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-321 Use of Hard-coded Cryptographic Key CWE-345 Insufficient Verification of Data Authenticity CWE-353 Missing Support for Integrity Check CWE-400 Uncontrolled Resource Consumption CWE-476 NULL Pointer Dereference CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort