HALO Link Image Management System
Digital pathology image management software. Attributes come from Leica Biosystems's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-2322 Device deploys an access enforcement/privilege mechanism PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-34 Device stores logs of application events and information PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Generic Application Local Application Local Service Operating System User Interface Web Application
Attributes: interface types
TCP
Attributes: assets
Log Data Model Data Software Configuration User Data
Attributes: dataflows
1D/2D barcodes to HALO Link (parsed slide information) HALO Link to HALO (annotations and analysis results via shared database) HALO Link to LIS/LIMS systems via API HALO Link to collaborators (shared slides, markups and analysis results) HALO Link to third-party image analysis platforms via API Slide scanners to HALO Link (new images and data) Third-party databases to HALO Link (images and data)
Matched threat intel
Top 20 of 41
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Leica Biosystems has said.
| # | Advisory | Date | Shared | Leica Biosystems status |
|---|---|---|---|---|
| 1 | Philips IntelliBridge Enterprise writes plaintext EMR credentials into its transaction logs | Jun 11, 2020 | Same property (MITRE EMB3D)PID-347 shared attributes: User accounts, Web interface, Device stores logs of application events and information (PID-34), Device includes the usage of a web/HTTP applications (PID-311) +3 | No response from manufacturer |
| 2 | Philips DoseWise Portal hard-codes its database credentials and stores logins in clear text | Aug 17, 2017 | Same property (MITRE EMB3D)PID-3326 shared attributes: Patient or study database, User accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311) +2 | No response from manufacturer |
| 3 | A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | 14 shared attributesImaging family, Web interface, User accounts, Role-based access +10 | No response from manufacturer |
| 4 | Five flaws in Sante PACS Server, and one sends credentials in cleartext | Aug 12, 2025 | 15 shared attributesImaging family, Image, HL7 or FHIR integration, User accounts +11 | No response from manufacturer |
| 5 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | 11 shared attributesPatient or study database, Web interface, User accounts, Remote access +7 | No response from manufacturer |
| 6 | Cl0p lists Philips among nearly 50 victims of its PTC Windchill campaign | Aug 14, 2026 | 12 shared attributesUser accounts, Remote access, Web interface, Patient or study database +8 | No response from manufacturer |
| 7 | Unrestricted file upload on a PACS points straight at code execution | Apr 10, 2025 | 11 shared attributesImaging family, File import, Patient or study database, Web interface +7 | No response from manufacturer |
| 8 | CISA spent the summer working through the DICOM stack | Aug 11, 2026 | 9 shared attributesImaging family, Image, Web interface, User accounts +5 | No response from manufacturer |
| 9 | A bundled message broker shipped with guest:guest still enabled | May 29, 2026 | 13 shared attributesDigital, Pathology, User accounts, Remote access +9 | No response from manufacturer |
| 10 | An open-source DICOM server that shipped with auth off by default | Feb 6, 2025 | 11 shared attributesImaging family, Remote access, User accounts, Patient or study database +7 | No response from manufacturer |
| 11 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | 9 shared attributesUser accounts, Web interface, Remote access, Device includes the usage of a web/HTTP applications (PID-311) +5 | No response from manufacturer |
| 12 | Pixmeo OsiriX MD crashes on crafted DICOM files and sends web portal credentials in cleartext | May 8, 2025 | 9 shared attributesImaging family, Image, File import, Web interface +5 | No response from manufacturer |
| 13 | A hospital management backend leaked its own system information | Oct 28, 2025 | 10 shared attributesRemote access, User accounts, Web interface, Role-based access +6 | No response from manufacturer |
| 14 | Login credentials exposed on the workstation in a GE imaging viewer | Mar 16, 2026 | 9 shared attributesImaging family, Image, User accounts, Web interface +5 | No response from manufacturer |
| 15 | Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | 9 shared attributesWeb interface, HL7 or FHIR integration, User accounts, Device includes the usage of a web/HTTP applications (PID-311) +5 | No response from manufacturer |
| 16 | ZOLL Defibrillator Dashboard lets non-admin users upload files that run commands | Jun 10, 2021 | 7 shared attributesWeb interface, File import, Role-based access, User accounts +3 | No response from manufacturer |
| 17 | Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | 9 shared attributesDevice includes the usage of a web/HTTP applications (PID-311), Device includes authenticated services (PID-332), Application-level software is present and running on the device (PID-31), Device exposes remote network services (PID-41) +5 | No response from manufacturer |
| 18 | Six flaws in J4Care's dcm4chee-arc-light let attackers delete or tamper with stored medical images | Oct 15, 2026 | 10 shared attributesImaging family, Image, Device exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411) +6 | No response from manufacturer |
| 19 | Carestream Vue RIS leaks technical details in HTTP 500 error pages | Oct 4, 2018 | 8 shared attributesImaging family, Web interface, Patient or study database, Device includes the usage of a web/HTTP applications (PID-311) +4 | No response from manufacturer |
| 20 | OpenClinic GA advisory lists authentication bypass, file upload and SQL abuse flaws | Jul 2, 2020 | 7 shared attributesUser accounts, Role-based access, Patient or study database, File import +3 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-116 Latent Privileged Access Port TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-226 Device leaks security information in logs TID-302 Install Untrusted Application TID-304 Manipulate Runtime Environment TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-405 Network Stack Resource Exhaustion TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-122 Heap-based Buffer Overflow CWE-125 Out-of-bounds Read CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-294 Authentication Bypass by Capture-replay CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-787 Out-of-bounds Write CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort