LIVE FEED
CISA added CVE-2026-90817, a critical REDCap flaw requiring no authentication, to its Known Exploited Vulnerabilities catalog November 18 after an unidentified actor used it to deploy the XMRig cryptominer; the research data platform drew a year-long China-nexus intrusion Google reported in June. The extortion group Falcon claimed a 104.76 GB haul from Fisher & Paykel Healthcare November 23, including device documentation and a full Salesforce CRM export, a month after the company confirmed a narrower breach limited to two employee email accounts. The extortion group n0n named GRAIL and Guardant Health, two oncology diagnostics companies, in sequential leak-site listings November 19 and 20, claiming provider and order records; neither company has confirmed the claims. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers and medical and insurance information. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop. CISA added CVE-2026-90817, a critical REDCap flaw requiring no authentication, to its Known Exploited Vulnerabilities catalog November 18 after an unidentified actor used it to deploy the XMRig cryptominer; the research data platform drew a year-long China-nexus intrusion Google reported in June. The extortion group Falcon claimed a 104.76 GB haul from Fisher & Paykel Healthcare November 23, including device documentation and a full Salesforce CRM export, a month after the company confirmed a narrower breach limited to two employee email accounts. The extortion group n0n named GRAIL and Guardant Health, two oncology diagnostics companies, in sequential leak-site listings November 19 and 20, claiming provider and order records; neither company has confirmed the claims. Prism Medical Products began notifying as many as 1.33 million people November 17 after discovering unauthorized access to its network on October 19; exposed data may include Social Security numbers and medical and insurance information. Amazon reported November 20 that autonomous AI agents it links with moderate confidence to a China nexus found and exploited a zero-day path traversal flaw in MONAI Label, an open source medical imaging tool, reaching a root shell in about 11 minutes; a fix is pending in an open pull request. FDA issued a discussion paper November 6 on cyber and AI risks in robotic medical devices with autonomous or remote teleoperation, warning errors could execute before a supervising clinician can intervene; comments are due January 5, 2027 ahead of a December 2 to 3 workshop.
Wednesday, November 25, 2026 Issue #524  ·  Est. 2025
Independent brief for device makers

HemoCue Hb 201 DM System

Point-of-care hemoglobin analyzer system. Attributes come from HemoCue's own public documentation for this product.

Attributes

Attributes: component types
API Battery Display Generic Hardware Local Application Local Service Operating System Storage User Interface
Attributes: interface types
Ethernet
Attributes: assets
Log Data Patient Data User Data
Attributes: dataflows
Analyzer to Docking Station (data transfer and charging) Analyzer to existing software/network via POCT1-A (patient information, comments and test results) PDS+ Docking Station to Network via LAN cable SDS+ Docking Station to PDS+ Docking Station

Matched threat intel

10

Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what HemoCue has said.

#AdvisoryDateSharedHemoCue status
1Baxter PrismaFlex and PrisMax send treatment data to EMR systems without encryption or authenticationJun 18, 2020Same property (MITRE EMB3D)PID-4113 shared attributes: Hospital network, Generic Hardware, Patient DataNo response from manufacturer
2Roche Accu-Chek and CoaguChek point of care handhelds expose a weakly protected service interfaceNov 6, 20189 shared attributesLab and diagnostics family, Point, Care, Wired network +5No response from manufacturer
3DNA analyzer output could be tampered with, and the software would not noticeAug 4, 20268 shared attributesLab and diagnostics family, Analyzer, Patient or study database, Handles patient data +4No response from manufacturer
4Dräger Infinity Delta monitors allow kiosk escape, reboot loops and unauthenticated log accessJan 22, 20197 shared attributesWired network, Hospital network, Device stores logs of system events and information (PID-28), Operating System +3No response from manufacturer
5Beckman Coulter maps PrintNightmare print spooler flaws across its lab instrument lineAug 13, 20216 shared attributesLab and diagnostics family, Analyzer, Wired network, Hospital network +2No response from manufacturer
6Beckman Coulter issues per-instrument guidance as Petya ransomware spreads through EternalBlueJun 28, 20176 shared attributesLab and diagnostics family, Analyzer, Wired network, Hospital network +2No response from manufacturer
7Beckman Coulter publishes WannaCry guidance for lab instruments missing MS17-010May 19, 20175 shared attributesLab and diagnostics family, Analyzer, Wired network, Hospital network +1No response from manufacturer
8BD tests Microsoft's Bad Neighbor patch for FACS, Pyxis and Rowa productsDec 3, 20204 shared attributesLab and diagnostics family, Point, Care, Operating SystemNo response from manufacturer
9Siemens Healthineers reports two vulnerabilities in RAPIDLab 1200 and RAPIDPoint blood gas analyzersJun 12, 20183 shared attributesLab and diagnostics family, Analyzer, Hospital networkNo response from manufacturer
10When 75,000 firewalls leak, even the unaffected have to answer for itJun 30, 20263 shared attributesDevice exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Device stores logs of system events and information (PID-28)No response from manufacturer

Threats and weaknesses in matched advisories