Vivid iq
System, Imaging, Pulsed Doppler, Ultrasonic. Attributes come from GE HealthCare's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-27 Device includes support for firmware/software updates PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services
Attributes: component types
Battery Circuit Board Display Firmware Generic Application Local Application Local Service Sensor Modules Storage User Interface
Attributes: interface types
USB Wireless
Attributes: dataflows
Cardiac signal input to Vivid iq for cardiac gating Vivid iq to printing devices
Matched threat intel
6
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what GE HealthCare has said.
| Advisory | Date | Shared | GE HealthCare status |
|---|---|---|---|
| Two maximum-severity flaws in a ventilation system | Nov 14, 2024 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| Boston Scientific ZOOM LATITUDE PRM Model 3120 accepts unsigned software from USB and can be re-regioned | Sep 30, 2021 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| GE Aestiva and Aespire anesthesia devices can have alarms silenced through unsecured terminal servers | Jul 9, 2019 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| Philips Veradius Unity, Pulsera and Endura Dual WAN routers use weak encryption | Dec 19, 2019 | Same signals | No feedback feed from manufacturer |
| Empty passwords and cleartext storage in a home cardiac monitor | Jul 24, 2025 | Exposed to the same EMB3D threatTID-111 | No feedback feed from manufacturer |
| Philips Gemini PET/CT systems write sensitive data to removable media without access control | Mar 25, 2021 | Exposed to the same EMB3D threatTID-111 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1188 Insecure Default Initialization of Resource CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-319 Cleartext Transmission of Sensitive Information CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-639 Authorization Bypass Through User-Controlled Key