DxONE Workflow Manager
Laboratory workflow automation software. Attributes come from Beckman Coulter's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-27 Device includes support for firmware/software updates PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Cloud Application Firmware Generic Application Local Application Local Service User Interface
Attributes: interface types
TCP
Attributes: assets
Patient Data Report Data Software Configuration
Attributes: dataflows
DxONE Workflow Manager to LIS (accepted results) Instruments to LIS via DxONE Workflow Manager
Matched threat intel
20
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Beckman Coulter has said.
| # | Advisory | Date | Shared | Beckman Coulter status |
|---|---|---|---|---|
| 1 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | Same property (MITRE EMB3D)PID-41111 shared attributes: Patient or study database, Handles patient data, Cloud connectivity, Web interface +7 | No response from manufacturer |
| 2 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | Same property (MITRE EMB3D)PID-4118 shared attributes: Lab and diagnostics family, Web interface, Handles patient data, Cloud connectivity +4 | No response from manufacturer |
| 3 | Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | Same property (MITRE EMB3D)PID-4115 shared attributes: Cloud connectivity, Handles patient data, Web interface, TCP +1 | No response from manufacturer |
| 4 | Default credentials across a line of diagnostic instruments | Dec 17, 2024 | 10 shared attributesLab and diagnostics family, Laboratory, Automation, Handles patient data +6 | No response from manufacturer |
| 5 | Siemens Healthineers lists imaging and lab products affected by DejaBlue Remote Desktop flaws | Sep 10, 2019 | 7 shared attributesLab and diagnostics family, Laboratory, Manager, Hospital network +3 | No response from manufacturer |
| 6 | BD Kiestra TLA, WCA and InoqulA+ database open through SMB1 and default credentials | May 16, 2017 | 9 shared attributesLab and diagnostics family, Automation, Patient or study database, Handles patient data +5 | No response from manufacturer |
| 7 | BD Kiestra lab automation lets privileged accounts issue SQL commands that can corrupt data | May 22, 2018 | 8 shared attributesLab and diagnostics family, Automation, Patient or study database, Handles patient data +4 | No response from manufacturer |
| 8 | BD Kiestra PerformA and KLA Journal Service use a hard-coded database password | Mar 23, 2017 | 7 shared attributesLab and diagnostics family, Automation, Patient or study database, Handles patient data +3 | No response from manufacturer |
| 9 | QuidelOrtho will ship Solana instruments with security features on and skips a software fix | Jan 17, 2024 | 6 shared attributesLab and diagnostics family, Laboratory, Remote access, Local Service +2 | No response from manufacturer |
| 10 | Beckman Coulter issues per-instrument guidance as Petya ransomware spreads through EternalBlue | Jun 28, 2017 | 6 shared attributesLab and diagnostics family, Automation, Hospital network, Local Application +2 | No response from manufacturer |
| 11 | Illumina Universal Copy Service on sequencers binds to every IP address and runs with excess privileges | Apr 27, 2023 | 7 shared attributesLab and diagnostics family, Device exposes remote network services (PID-41), Local Service, Local Application +3 | No response from manufacturer |
| 12 | BD lists FocalPoint, Kiestra and BD MAX in scope for three Remote Desktop flaws | Apr 3, 2020 | 5 shared attributesLab and diagnostics family, Automation, Remote access, Local Service +1 | No response from manufacturer |
| 13 | Researchers found 1.2 million healthcare devices exposed online, images and all | Aug 7, 2025 | 6 shared attributesDevice exposes remote network services (PID-41), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Device includes support for firmware/software updates (PID-27), Firmware +2 | No response from manufacturer |
| 14 | Philips IntelliBridge EC40 and EC80 hubs allow weak SSH ciphers | Nov 14, 2019 | 7 shared attributesRemote access, Handles patient data, Device exposes remote network services (PID-41), Local Service +3 | No response from manufacturer |
| 15 | $9.8 million says product security is now a False Claims Act problem | Aug 1, 2025 | 6 shared attributesLab and diagnostics family, Application-level software is present and running on the device (PID-31), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Device exposes remote network services (PID-41) +2 | No response from manufacturer |
| 16 | Beckman Coulter patches DxONE Insights for Log4j and gives Command Central and LabPro guidance | Dec 13, 2021 | 4 shared attributesLab and diagnostics family, Laboratory, Patient or study database, Local Service | No response from manufacturer |
| 17 | BD Viper LT system uses hard-coded credentials that expose patient data | Mar 3, 2022 | 5 shared attributesLab and diagnostics family, Laboratory, Handles patient data, Generic Application +1 | No response from manufacturer |
| 18 | BD finds Ripple20 Treck TCP/IP stack in Kiestra and Rowa components | Jul 30, 2020 | 3 shared attributesLab and diagnostics family, Automation, TCP | No response from manufacturer |
| 19 | Quest Diagnostics discloses breach of its Quanum lab ordering system | Oct 22, 2026 | 5 shared attributesLab and diagnostics family, Device includes interactive applications, services, or user interfaces (PID-33), Application-level software is present and running on the device (PID-31), TCP +1 | No response from manufacturer |
| 20 | Thermo Fisher ePort software up to 3.0.0 carries improper access control flaw CVE-2025-32992 | Aug 18, 2025 | 3 shared attributesLab and diagnostics family, Laboratory, Local Application | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-210 Device Vulnerabilities Unpatchable TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-226 Device leaks security information in logs TID-302 Install Untrusted Application TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-319 Cleartext Transmission of Sensitive Information CWE-326 Inadequate Encryption Strength CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')