Embryo Assist
Embryo lab workflow software. Attributes come from Alife Health's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-34 Device stores logs of application events and information PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Cloud Application Generic Application Local Application Local Service User Interface
Attributes: interface types
TCP
Attributes: assets
Log Data Report Data Sensor Data
Attributes: dataflows
Embryo Assist to EMR system (real-time connection) Embryo Assist to patients (generated patient report) Existing imaging hardware to Embryo Assist (embryo images)
Matched threat intel
7
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Alife Health has said.
| # | Advisory | Date | Shared | Alife Health status |
|---|---|---|---|---|
| 1 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-41112 shared attributes: Lab and diagnostics family, Handles patient data, Remote access, Cloud connectivity +8 | No response from manufacturer |
| 2 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-4118 shared attributes: Remote access, Hospital network, Device exposes remote network services (PID-41), Device includes interactive applications, services, or user interfaces (PID-33) +4 | No response from manufacturer |
| 3 | Baxter PrismaFlex and PrisMax send treatment data to EMR systems without encryption or authentication | Jun 18, 2020 | Same property (MITRE EMB3D)PID-4113 shared attributes: Hospital network, Generic Application, TCP | No response from manufacturer |
| 4 | Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | 8 shared attributesLab and diagnostics family, Application-level software is present and running on the device (PID-31), Device exposes remote network services (PID-41), Device stores logs of application events and information (PID-34) +4 | No response from manufacturer |
| 5 | BD Kiestra PerformA and KLA Journal Service use a hard-coded database password | Mar 23, 2017 | 5 shared attributesLab and diagnostics family, Patient or study database, Handles patient data, Generic Application +1 | No response from manufacturer |
| 6 | Philips DreamMapper 2.24 and earlier write attacker-useful details to log files | Jul 30, 2020 | 4 shared attributesDevice stores logs of application events and information (PID-34), Generic Application, TCP, Log Data | No response from manufacturer |
| 7 | $9.8 million says product security is now a False Claims Act problem | Aug 1, 2025 | 6 shared attributesLab and diagnostics family, Application-level software is present and running on the device (PID-31), Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations (PID-411), Device exposes remote network services (PID-41) +2 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1188 Insecure Default Initialization of Resource CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-306 Missing Authentication for Critical Function CWE-319 Cleartext Transmission of Sensitive Information CWE-326 Inadequate Encryption Strength CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials