RescueNet Live
Telehealth data streaming software. Attributes come from ZOLL's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services PID-411 Device exposes remote services with the ability to send, receive, view or modify sensitive information or configurations
Attributes: component types
API Generic Application Local Application Local Service User Interface
Attributes: assets
Patient Data Sensor Data
Attributes: dataflows
CodeWriter notes to CaseReview via CodeNet Connected defibrillators to DeviceDashboard EMS to hospital via RescueNet 12-Lead (12-lead data) EMS to hospitals and vendors via ZOLL Care Exchange ZOLL AEDs to RescueNet EventSummary ZOLL monitor/defibrillator to clinicians via RescueNet Live ZOLL monitor/defibrillator to hospital team via RescueNet Live
Matched threat intel
4
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what ZOLL has said.
| # | Advisory | Date | Shared | ZOLL status |
|---|---|---|---|---|
| 1 | Missing authentication on a DNA sequencer control plane | Oct 21, 2025 | Same property (MITRE EMB3D)PID-4119 shared attributes: Handles patient data, Remote access, User accounts, Cloud connectivity +5 | No response from manufacturer |
| 2 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | Same property (MITRE EMB3D)PID-4117 shared attributes: Remote access, User accounts, Device exposes remote network services (PID-41), Device includes interactive applications, services, or user interfaces (PID-33) +3 | No response from manufacturer |
| 3 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | Same property (MITRE EMB3D)PID-4115 shared attributes: Cloud connectivity, User accounts, Remote access, Handles patient data +1 | No response from manufacturer |
| 4 | Medtronic MyCareLink 24950 and 24952 monitors store upload credentials in a recoverable format | Aug 7, 2018 | Same property (MITRE EMB3D)PID-4113 shared attributes: Cloud connectivity, Handles patient data, Patient Data | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-221 Authentication Bypass By Message Replay TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-313 Unauthenticated Session Changes Credential TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1390 Weak Authentication CWE-1392 Use of Default Credentials CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-284 Improper Access Control CWE-287 Improper Authentication CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-321 Use of Hard-coded Cryptographic Key CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort