Chondral Quant
System, Image Processing, Radiological. Attributes come from Siemens Healthineers's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
Attributes: materials
syngo
Attributes: component types
Firmware Generic Application Local Application User Interface
Attributes: assets
Firmware
Matched threat intel
6
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what Siemens Healthineers has said.
| Advisory | Date | Shared | Siemens Healthineers status |
|---|---|---|---|
| Siemens Healthineers reports syngo deserialization flaw across CT, MRI, PET/CT and mammography systems | May 31, 2022 | Names the affected product | No feedback feed from manufacturer |
| Siemens Healthineers lists imaging and lab products affected by DejaBlue Remote Desktop flaws | Sep 10, 2019 | Names the affected product | No feedback feed from manufacturer |
| A DICOM viewer that did not check its update server certificate | Feb 20, 2025 | Same property (MITRE EMB3D)PID-27 | No feedback feed from manufacturer |
| MicroDicom DICOM Viewer 2024.03 fails to validate its update server certificate | Feb 6, 2025 | Same property (MITRE EMB3D)PID-27 | No feedback feed from manufacturer |
| A patient monitor with a hidden backdoor that phones home | Jan 30, 2025 | Same property (MITRE EMB3D)PID-27 | No feedback feed from manufacturer |
| Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their origin | Feb 27, 2018 | Same property (MITRE EMB3D)PID-27 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-116 Latent Privileged Access Port TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-310 Remotely Accessible Unauthenticated Services TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-323 Path Traversal TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1329 Reliance on Component That is Not Updateable CWE-345 Insufficient Verification of Data Authenticity CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-506 Embedded Malicious Code CWE-912 Hidden Functionality