MONARCH Platform
Bronchoscope (Flexible Or Rigid). Attributes come from Johnson & Johnson MedTech's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-14 Device includes external peripheral interconnects (e.g., USB, Serial) PID-27 Device includes support for firmware/software updates PID-31 Application-level software is present and running on the device PID-33 Device includes interactive applications, services, or user interfaces PID-41 Device exposes remote network services
Attributes: component types
Actuator Circuit Board Display Firmware Generic Application Generic Hardware Local Application Local Service Sensor Modules Storage User Interface
Attributes: interface types
Ethernet USB
Attributes: assets
Firmware Patient Data Software Code Software Update
Attributes: dataflows
Cone Beam CT System to MONARCH Platform (3D imaging data over Ethernet) Cone Beam CT System to MONARCH Platform over Ethernet (3D imaging data) Controller to Bronchoscope (user inputs via electromechanical system)
Matched threat intel
6
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what Johnson & Johnson MedTech has said.
| Advisory | Date | Shared | Johnson & Johnson MedTech status |
|---|---|---|---|
| A DICOM viewer that did not check its update server certificate | Feb 20, 2025 | Same property (MITRE EMB3D)PID-27 | No feedback feed from manufacturer |
| MicroDicom DICOM Viewer 2024.03 fails to validate its update server certificate | Feb 6, 2025 | Same property (MITRE EMB3D)PID-27 | No feedback feed from manufacturer |
| A patient monitor with a hidden backdoor that phones home | Jan 30, 2025 | Same property (MITRE EMB3D)PID-27 | No feedback feed from manufacturer |
| Medtronic 2090 CareLink and 29901 Encore programmers accept updates without verifying their origin | Feb 27, 2018 | Same property (MITRE EMB3D)PID-27 | No feedback feed from manufacturer |
| Baxter Welch Allyn Connex Spot Monitor used a default cryptographic key | May 30, 2024 | Same signals | No feedback feed from manufacturer |
| Medtronic CareLink 9790, 2090 and Encore 29901 programmers store patient data unencrypted | Dec 13, 2018 | Exposed to the same EMB3D threatTID-108 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-116 Latent Privileged Access Port TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-221 Authentication Bypass By Message Replay TID-224 Excessive Access via Software Diagnostic Features TID-310 Remotely Accessible Unauthenticated Services TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-323 Path Traversal TID-327 Out of Bounds Memory Access TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-294 Authentication Bypass by Capture-replay CWE-321 Use of Hard-coded Cryptographic Key CWE-345 Insufficient Verification of Data Authenticity CWE-494 Download of Code Without Integrity Check CWE-506 Embedded Malicious Code CWE-912 Hidden Functionality CWE-916 Use of Password Hash With Insufficient Computational Effort