DesignStudio Assay Design Tool
Custom assay design software. Attributes come from Illumina's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-41 Device exposes remote network services
Attributes: component types
Generic Application Local Application Local Service User Interface Web Application
Attributes: assets
Credentials
Matched threat intel
9
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Illumina has said.
| # | Advisory | Date | Shared | Illumina status |
|---|---|---|---|---|
| 1 | Stored passwords recoverable in a Siemens imaging platform | Feb 10, 2026 | Same signals5 shared attributes: User accounts, Web interface, Application-level software is present and running on the device (PID-31), Device includes interactive applications, services, or user interfaces (PID-33) +1 | No response from manufacturer |
| 2 | Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | 8 shared attributesLab and diagnostics family, Device includes the usage of a web/HTTP applications (PID-311), Device includes authenticated services (PID-332), Application-level software is present and running on the device (PID-31) +4 | No response from manufacturer |
| 3 | BeaconMedaes TotalAlert Scroll Medical Air Systems expose stored passwords to unauthenticated users | May 24, 2018 | 5 shared attributesUser accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application +1 | No response from manufacturer |
| 4 | BD Totalys MultiProcessor 1.70 and earlier uses hard-coded credentials | Oct 4, 2022 | 4 shared attributesLab and diagnostics family, User accounts, Device includes authenticated services (PID-332), Credentials | No response from manufacturer |
| 5 | Philips Clinical Collaboration Platform 12.2.1 and earlier has five web and authentication flaws | Sep 17, 2020 | 4 shared attributesWeb interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application | No response from manufacturer |
| 6 | BD Kiestra service credential surfaced in a public file-analysis report | Apr 24, 2023 | 3 shared attributesLab and diagnostics family, User accounts, Credentials | No response from manufacturer |
| 7 | Thermo Fisher updates Ion Torrent Genexus software after review finds unauthorized settings changes | Aug 13, 2026 | 4 shared attributesLab and diagnostics family, Assay, User accounts, Generic Application | No response from manufacturer |
| 8 | BD Viper LT system uses hard-coded credentials that expose patient data | Mar 3, 2022 | 3 shared attributesLab and diagnostics family, Generic Application, Credentials | No response from manufacturer |
| 9 | Thermo Fisher ePort software up to 3.0.0 carries improper access control flaw CVE-2025-32992 | Aug 18, 2025 | 3 shared attributesLab and diagnostics family, User accounts, Local Application | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-221 Authentication Bypass By Message Replay TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-328 Hardcoded Credentials TID-329 Improper Password Storage
CWE weaknesses
CWE-1392 Use of Default Credentials CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-284 Improper Access Control CWE-294 Authentication Bypass by Capture-replay CWE-321 Use of Hard-coded Cryptographic Key CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-916 Use of Password Hash With Insufficient Computational Effort