Clarity LIMS software
Laboratory information management system. Attributes come from Illumina's own public documentation for this product.
Attributes
Signals
Properties (MITRE EMB3D)
PID-2322 Device deploys an access enforcement/privilege mechanism PID-27 Device includes support for firmware/software updates PID-31 Application-level software is present and running on the device PID-311 Device includes the usage of a web/HTTP applications PID-33 Device includes interactive applications, services, or user interfaces PID-332 Device includes authenticated services PID-34 Device stores logs of application events and information PID-41 Device exposes remote network services
Attributes: component types
API Cloud Application Firmware Generic Application Local Application Local Service Operating System Storage User Interface Web Application
Attributes: interface types
TCP
Attributes: assets
Log Data Report Data Software Configuration Tokens User Data
Attributes: dataflows
Clarity LIMS to Illumina lab automation software to liquid-handling robots (sample placement location and container type Clarity LIMS to sequencing system (sample sheets) Clarity LIMS to third-party reporting tools (Advanced Search results) Submitters to Clarity LIMS via LabLink (sample submission) Third-party instruments and software to Clarity LIMS via API
Matched threat intel
Top 20 of 52
Advisories in our coverage that share attributes with this product, strongest first: a named product or component, the same device type or lineage, then the most shared attributes. A shared attribute is a lead, not a finding. The status column shows only what Illumina has said.
| # | Advisory | Date | Shared | Illumina status |
|---|---|---|---|---|
| 1 | A low-privilege user can walk past role limits in Synapse Mobility | Aug 21, 2025 | Same property (MITRE EMB3D)PID-232213 shared attributes: Web interface, User accounts, Role-based access, Cloud connectivity +9 | No response from manufacturer |
| 2 | ZOLL Defibrillator Dashboard lets non-admin users upload files that run commands | Jun 10, 2021 | Same property (MITRE EMB3D)PID-23227 shared attributes: Web interface, File import, Role-based access, User accounts +3 | No response from manufacturer |
| 3 | OpenClinic GA advisory lists authentication bypass, file upload and SQL abuse flaws | Jul 2, 2020 | Same property (MITRE EMB3D)PID-3117 shared attributes: User accounts, Role-based access, Patient or study database, File import +3 | No response from manufacturer |
| 4 | A 10.0 SQL injection on a patient health portal | Sep 5, 2024 | 11 shared attributesPatient or study database, Cloud connectivity, Web interface, User accounts +7 | No response from manufacturer |
| 5 | Dario Health glucose monitoring app and servers exposed cross-user health data | Feb 27, 2025 | 8 shared attributesCloud connectivity, Web interface, Device includes the usage of a web/HTTP applications (PID-311), Web Application +4 | No response from manufacturer |
| 6 | Fresenius Kabi Agilia Connect infusion accessories expose unauthenticated endpoints and weak TLS | Dec 21, 2021 | 10 shared attributesWeb interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application +6 | No response from manufacturer |
| 7 | B. Braun SpaceCom and Battery Pack SP with Wi-Fi carry 11 flaws from XSS to unsigned firmware | Oct 22, 2020 | 10 shared attributesWeb interface, Field-updatable firmware, User accounts, Device includes the usage of a web/HTTP applications (PID-311) +6 | No response from manufacturer |
| 8 | BD Alaris System with Guardrails Suite MX has unsigned wireless firmware and tamperable datasets | Jul 13, 2023 | 10 shared attributesField-updatable firmware, File import, Firmware, Web Application +6 | No response from manufacturer |
| 9 | CISA spent the summer working through the DICOM stack | Aug 11, 2026 | 8 shared attributesWeb interface, Cloud connectivity, User accounts, Device includes the usage of a web/HTTP applications (PID-311) +4 | No response from manufacturer |
| 10 | A hard-coded VNC password on a bioreactor, base score 9.8 | May 26, 2026 | 12 shared attributesUser accounts, Field-updatable firmware, Device includes authenticated services (PID-332), Device exposes remote network services (PID-41) +8 | No response from manufacturer |
| 11 | User enumeration on the CareLink Network, found at a conference | Dec 4, 2025 | 9 shared attributesCloud connectivity, User accounts, Web interface, Device includes the usage of a web/HTTP applications (PID-311) +5 | No response from manufacturer |
| 12 | Cl0p lists Philips among nearly 50 victims of its PTC Windchill campaign | Aug 14, 2026 | 12 shared attributesCloud connectivity, User accounts, Web interface, Patient or study database +8 | No response from manufacturer |
| 13 | Path traversal in Thermo Fisher's Torrent Suite lets authenticated users read server files | Oct 15, 2026 | 10 shared attributesLab and diagnostics family, Device includes the usage of a web/HTTP applications (PID-311), Device includes authenticated services (PID-332), Application-level software is present and running on the device (PID-31) +6 | No response from manufacturer |
| 14 | One AES key, shared across every install of a cardiovascular system | Mar 13, 2025 | 8 shared attributesInformation, User accounts, Cloud connectivity, Patient or study database +4 | No response from manufacturer |
| 15 | Default credentials across a line of diagnostic instruments | Dec 17, 2024 | 8 shared attributesLab and diagnostics family, Laboratory, User accounts, Web interface +4 | No response from manufacturer |
| 16 | Silex modules in GE MobileLink allow unauthenticated setting changes and command injection | May 8, 2018 | 9 shared attributesWeb interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Device includes support for firmware/software updates (PID-27) +5 | No response from manufacturer |
| 17 | Philips Tasy EMR and WebPortal carry cross-site scripting and information exposure flaws | Apr 30, 2019 | 9 shared attributesWeb interface, User accounts, Device includes the usage of a web/HTTP applications (PID-311), Web Application +5 | No response from manufacturer |
| 18 | A hospital management backend leaked its own system information | Oct 28, 2025 | 9 shared attributesUser accounts, Cloud connectivity, Web interface, Role-based access +5 | No response from manufacturer |
| 19 | LifePoint Informatics Patient Portal generated lab report PDFs from a URL and a patient ID | Apr 5, 2022 | 8 shared attributesLab and diagnostics family, Web interface, Cloud connectivity, Patient or study database +4 | No response from manufacturer |
| 20 | DNA analyzer output could be tampered with, and the software would not notice | Aug 4, 2026 | 9 shared attributesLab and diagnostics family, File import, Patient or study database, User accounts +5 | No response from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-202 Exploitable System Network Stack Component TID-204 Untrusted Programs Can Access Privileged OS Functions TID-205 Existing OS Tools Maliciously Used for Device Manipulation TID-210 Device Vulnerabilities Unpatchable TID-211 Device Allows Unauthenticated Firmware Installation TID-213 Faulty FW/SW Update Integrity Verification TID-215 Unencrypted SW/FW Updates TID-219 OS/Kernel Privilege Escalation TID-221 Authentication Bypass By Message Replay TID-222 Critical System Service May Be Disabled TID-224 Excessive Access via Software Diagnostic Features TID-225 Logs can be manipulated on the device TID-226 Device leaks security information in logs TID-301 Applications Binaries Modified TID-302 Install Untrusted Application TID-304 Manipulate Runtime Environment TID-305 Program Executes Dangerous System Calls TID-310 Remotely Accessible Unauthenticated Services TID-311 Default Credentials TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-317 Predictable Cryptographic Key TID-319 Cross Site Scripting (XSS) TID-320 SQL Injection TID-321 HTTP Application Session Hijacking TID-323 Path Traversal TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-327 Out of Bounds Memory Access TID-328 Hardcoded Credentials TID-329 Improper Password Storage TID-401 Undocumented Protocol Features TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-408 Unencrypted Sensitive Data Communication TID-411 Weak/Insecure Cryptographic Protocol
CWE weaknesses
CWE-1104 Use of Unmaintained Third Party Components CWE-1188 Insecure Default Initialization of Resource CWE-1329 Reliance on Component That is Not Updateable CWE-1392 Use of Default Credentials CWE-1395 Dependency on Vulnerable Third-Party Component CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-22 Improper Limitation of a Pathname to a Restricted Directory CWE-276 Incorrect Default Permissions CWE-284 Improper Access Control CWE-294 Authentication Bypass by Capture-replay CWE-319 Cleartext Transmission of Sensitive Information CWE-321 Use of Hard-coded Cryptographic Key CWE-326 Inadequate Encryption Strength CWE-345 Insufficient Verification of Data Authenticity CWE-353 Missing Support for Integrity Check CWE-427 Uncontrolled Search Path Element CWE-434 Unrestricted Upload of File with Dangerous Type CWE-494 Download of Code Without Integrity Check CWE-502 Deserialization of Untrusted Data CWE-522 Insufficiently Protected Credentials CWE-639 Authorization Bypass Through User-Controlled Key CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') CWE-798 Use of Hard-coded Credentials CWE-89 Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') CWE-916 Use of Password Hash With Insufficient Computational Effort