Carescape B650
Monitor, Physiological, Patient(With Arrhythmia Detection Or Alarms). Attributes come from GE HealthCare's own public documentation for this product.
Attributes
Properties (MITRE EMB3D)
Attributes: component types
Circuit Board Generic Application Local Application Local Service User Interface
Attributes: assets
Telemetry Data
Matched threat intel
4
Advisories in our coverage that share an attribute with this product. A shared attribute is a lead, not a finding. The status column shows only what GE HealthCare has said.
| Advisory | Date | Shared | GE HealthCare status |
|---|---|---|---|
| Two maximum-severity flaws in a ventilation system | Nov 14, 2024 | Same property (MITRE EMB3D)PID-14 | No feedback feed from manufacturer |
| Missing authentication lets an attacker rewrite a cardiac wearable | May 28, 2026 | Same signals | No feedback feed from manufacturer |
| Empty passwords and cleartext storage in a home cardiac monitor | Jul 24, 2025 | Exposed to the same EMB3D threatTID-111 | No feedback feed from manufacturer |
| Philips Gemini PET/CT systems write sensitive data to removable media without access control | Mar 25, 2021 | Exposed to the same EMB3D threatTID-111 | No feedback feed from manufacturer |
Threats and weaknesses in matched advisories
MITRE EMB3D threats
TID-111 Untrusted External Storage TID-115 Firmware/Data Extraction via Hardware Interface TID-116 Latent Privileged Access Port TID-119 Latent Hardware Debug Port Allows Memory/Code Manipulation TID-226 Device leaks security information in logs TID-310 Remotely Accessible Unauthenticated Services TID-314 Passwords Can Be Guessed Using Brute-Force Attempts TID-316 Incorrect Certificate Verification Allows Authentication Bypass TID-324 HTTP Direct Object Reference TID-326 Insecure Deserialization TID-328 Hardcoded Credentials TID-404 Remotely Triggerable Deadlock/DoS TID-406 Unauthorized Messages or Connections TID-407 Missing Message Replay Protection TID-408 Unencrypted Sensitive Data Communication
CWE weaknesses
CWE-1191 On-Chip Debug and Test Interface With Improper Access Control CWE-1313 Hardware Allows Activation of Test or Debug Logic at Runtime CWE-200 Exposure of Sensitive Information to an Unauthorized Actor CWE-284 Improper Access Control CWE-290 Authentication Bypass by Spoofing CWE-294 Authentication Bypass by Capture-replay CWE-306 Missing Authentication for Critical Function CWE-502 Deserialization of Untrusted Data CWE-639 Authorization Bypass Through User-Controlled Key